500/7D Explosion-proof pressure controller
■ The controller uses diaphragm sensors for neutral gases such as air and liquid media such as water, hydraulic oil, lubricating oil and light fuel.
■ The setting value of the controller is adjustable, and the adjustment range is 0 to 2.5MPa.
■ High control sensitivity
- Price Term: FOB/CIF/EXW/DAP
- Package: Exported Wooden case or according to customer request
- Delivery Time: 7 to 10 working days
- Transports: By sea, by air, by high express
- Shipment Port: Shanghai Port
- Origin of Place: Jiangsu
- Warranty: 12 Months
- Main Technical Performance
- Specification
- External And Mounting Dimensions (unit: mm)
Normal Type | Explosion-proof | |
Operating Viscosity | <1×10-3m2/s | <1×10-3m2/s |
Switching Element | Micro switch | Sealed Switches |
Explosion Protection Class | — | Exde Ⅱ CT4~T6 Certificate of Conformity |
Enclosure Protection Level | IP65(Conforms to DIN40050, equivalent to IP65 in GB4208) | IP65 (Conforms to DIN40050, equivalent to IP65 in GB4208) |
Ambient Temperature | -20℃~50℃ | -20℃~50℃ |
Medium Temperature | 0~90℃ | 0~120℃ |
Installation Position | — | Pressure connection vertically down |
Anti-Vibration Performance | 500/7D: 40m/s2 ; 500/7DK:20m/s2 | Max: 20m/s2 |
Repeatability Error | ≤1.5% | ≤1.5% |
Contact Capacity | AC 220V 6A (Resistance) | DC 250V 0.25A(Resistance) 60Wmax
AC 250V 5A(Resistance) 1250VAmax |
500/7D Micro-Pressure Controller Switching Differential Non-Adjustable
Set Value
Adjustment Range Kpa |
Switching
Difference Is Not Greater Than Kpa |
Maximum Allowable Pressure
①Kpa |
Switching Times
Times/Min |
Pressure Sensor Materials | Interface Female Thread | W
(Kg) |
Dimension Drawing | ||
Housing | Diaphragm | Normal | Ex-Proof | ||||||
-16~0 | 0.6 | 50 | 10 | Galvanized steel | Nitrile
Rubber |
G1/4″ | 1.0 | 01 | 04 |
-10~0 | 0.6 | ||||||||
-6~0 | 0.6 | ||||||||
-2.5~0 | 0.4 | ||||||||
-1.6~0 | 0.4 | ||||||||
0~0.6 | 0.2 | ||||||||
0~1.1 | 0.4 | ||||||||
0~1.6 | 0.4 |
500/7D Switching Difference Is Not Adjustable
Set Value
Adjustment Range Mpa (Kpa) |
Switching
Difference Is Not Greater Than Mpa(Kpa) |
Maximum Allowable Pressure
① Mpa(Kpa) |
Switching Times
Times/Min |
Pressure Sensor Materials | Interface Female Thread | W
(Kg) |
Dimension Drawing | ||
Housing | Diaphragm | Normal | Ex-Proof | ||||||
(0~2.5) | (0.4) | (50) | 10 | Galvanized Steel | Nitrile
Rubber |
G1/4″ | 1.0 | 01 | 04 |
(0~6) | (0.6) | ||||||||
(0~16) | (0.8) | ||||||||
(0~25) | (0.9) | ||||||||
0.005~0.06 | 0.006 | 1.5 | 40 | Brass | 1.15 | 02 | 05 | ||
0.005~0.1 | 0.009 | ||||||||
0.05~0.16 | 0.012 | ||||||||
0.05~0.25 | 0.015 | ||||||||
0.03~0.4 | 0.04 | 4 | 0.85 | 03 | 06 | ||||
0.03~0.6 | 0.05 | ||||||||
0.05~1 | 0.06 | ||||||||
0.1~1.6 | 0.12 | 5 | 0.85 | 03 | 06 | ||||
0.1~2.5 | 0.15 |
500/7D Switching Difference Adjustable
Set Value
Adjustment Range Mpa (Kpa) |
Switching
Difference Is Not Greater Than Mpa(Kpa) |
Maximum Allowable Pressure
① Mpa(Kpa) |
Switching Times
Times/Min |
Pressure Sensor Materials | Interface Female Thread | W
Kg |
Dimension Drawing | ||
Housing | Diaphragm | Normal | Ex-Proof | ||||||
(0~2.5) | (1.1) | (50) | 10 | Galvanized Steel | Nitrile
Rubber |
G1/4″ | 1.05 | 01 | 04 |
(0~6) | (1.5) | ||||||||
(0~16) | (2.3) | ||||||||
(0~25) | (2.8) | ||||||||
0.005~0.06 | 0.016 | 1.5 | 40 | Brass | 1.20 | 02 | 05 | ||
0.005~0.1 | 0.018 | ||||||||
0.05~0.16 | 0.025 | ||||||||
0.05~0.25 | 0.025 | ||||||||
0.03~0.4 | 0.08 | 4 | 0.9 | 03 | 06 | ||||
0.03~0.6 | 0.1 | ||||||||
0.05~1 | 0.11 | ||||||||
0.1~1.6 | 0.25 | 5 | 0.9 | 03 | 06 | ||||
0.1~2.5 | 0.33 |
500/7DK Switching Difference Is Not Adjustable (Small Switching Difference, No Explosion-Proof Type)
Set Value
Adjustment Range Mpa (Kpa) |
Switching
Difference Is Not Greater Than Mpa(Kpa) |
Maximum Allowable Pressure
① Mpa(Kpa) |
Switching Times
Times/Min |
Pressure Sensor Materials | Interface Female Thread | W
kg |
Dimension Drawing | |
Housing | Diaphragm | |||||||
(0~2.5) | (0.2) | (50) | 10 | Galvanized Steel | Nitrile
Rubber |
G1/4″ | 1.0 | 01 |
(0~6) | (0.45) | |||||||
(0~16) | (0.5) | |||||||
(0~25) | (0.6) | |||||||
0.005~0.06 | 0.004 | 1.5 | 40 | Brass | 1.15 | 02 | ||
0.005~0.1 | 0.006 | |||||||
0.005~0.16 | 0.0075 | |||||||
0.005~0.25 | 0.01 | |||||||
0.03~0.4 | 0.02 | 4 | 0.85 | 03 | ||||
0.03~0.6 | 0.02 | |||||||
0.05~1 | 0.038 | |||||||
0.1~1.6 | 0.08 | 5 | 0.85 | 03 | ||||
0.1~2.5 | 0.1 |
Note: ① In practice, even brief pressure peaks must not exceed this value.
Selection And Installation
For details, see Selection and installation of pressure controller
Adjustment Of The Set Value
See the adjustment of the set value of the pressure controller for example one, example two, example five
Normal Type
01
02
03
04
05
06