501/7D Explosion-proof Pressure Controller

 The controller adopts diaphragm type sensor, some specifications of the sensor shell material is stainless steel, can be used for corrosive media, also can be used for air, gas, water vapor and other neutral gases and oil and other liquid media.

 The setting value of the controller is adjustable,The adjustment range is 0~1MPa.

 High control sensitivity in the low pressure range.

  • Price Term: FOB/CIF/EXW/DAP
  • Package: Exported Wooden case or according to customer request
  • Delivery Time:  7 to 10 working days
  • Transports: By sea, by air, by high express
  • Shipment Port: Shanghai Port
  • Origin of Place: Jiangsu
  • Warranty: 12 Months
Normal  Type Explosion-proof
Operating Viscosity <1×10-3m2/s <1×10-3m2/s
Switching Element Micro switch Sealed Switches
Explosion Protection Class Exde Ⅱ CT4~T6 Certificate of Conformity No
Enclosure Protection Level IP65(Conforms to DIN40050, equivalent to  IP65 in GB4208) IP54 (Conforms to DIN40050, equivalent to  IP54  in  GB4208)
Ambient Temperature -20℃~50℃ -20℃~50℃
Medium Temperature 0~120℃ 0~120℃
Installation Position Pressure connection vertically down
Anti-Vibration Performance 20m/s2 Max: 20m/s2
Repeatability Error ≤1.5% ≤1.5%
Contact Capacity AC  220V  6A (Resistance) DC 250V  0.25A(Resistance)  60Wmax

AC 250V  5A(Resistance)  1250VAmax

501/7D Switching Difference Is Not Adjustable 

Set Value

Adjustment

Range  Mpa

Switching

Difference Is Not Greater Than  Mpa

Maximum Allowable Pressure

Mpa

Switching Times Times/Min Pressure Sensor Materials Interface Female Thread    W

Kg

Dimension Drawing
Housing Diaphragm Normal Ex-Proof
0~0.01 0.0012  

0.1

10 Stainless Steel Stainless Steel

00Cr17Ni14

Mo2

(316L)

 

G1/4″

 

0.9

01 03
0~0.025 0.0018
0~0.04 0.0025
0.05~0.4 0.06 10② Stainless Steel

1Cr18Ni

9Ti

02 04
0.05~0.6 0.07
0.05~1 0.1

 

501/7D Switching Difference Is Adjustable

Set Value

Adjustment

Range Mpa

Switching

Difference Is Not Greater Than  Mpa

Maximum Allowable Pressure

Mpa

Switching Times

Times/Min

Pressure Sensor Materials Interface Female Thread W

Kg

Dimension Drawing
Housing Diaphragm Normal Ex-Proof
0~0.01 0.004  

0.1

10 Stainless Steel Stainless Steel

00Cr17Ni14

Mo2

(316L)

G1/4″ 0.95 01 03
0~0.025 0.005 0.9
0~0.04 0.007 0.95
0.05~0.4 0.18 10② Stainless Steel

1Cr18Ni

9Ti

0.95 02 04
0.05~0.6 0.22
0.05~1 0.3

 

501/7DK Switching Difference Is Not Adjustable (Small Switching Difference, No Explosion-Proof Type)

 

Set Value

Adjustment

Range  Mpa

Switching

Difference Is Not Greater Than   Mpa

Maximum Allowable Pressure

Mpa

Switching

Times

Times/Min

 

Pressure Sensor Materials Interface Female Thread W

Kg

Dimension Drawing
Housing Diaphragm Normal Ex-Proof
0~0.01 0.0006 0.1 10 Stainless Steel Stainless Steel

00Cr17Ni14

Mo2

(316L)

G1/4″ 0.9 01
0~0.025 0.001
0~0.04 0.0018
0.05~0.4 0.035 10② Stainless Steel

1Cr18Ni

9Ti

02
0.05~0.6 0.04
0.05~1 0.05

Note: ①In practice, even brief pressure peaks must not exceed this value.

② refers to the static pressure value

 

Adjustment Of The Set Value

See the adjustment of the set value of the pressure controller in Example 1, Example 2 and Example 5

Selection And Installation

See Selection and installation of the controller for details

Normal  Type

01

501/7D Explosion-proof Pressure Controller

02

Pressure Controller

Ex-proof  Type

03

Explosion-proof Pressure Controller

04

Explosion-proof Pressure Controller

Get Our Best Quotation




    Scroll to Top