502/7D-C (Small) Pressure Controller

 Model 502/7D-C Pressure Controller adopts bellows type sensor and can be used for neutral gases such as air, gas, water and liquid media such as lubricating oil and light fuel.

 The setting value of the controller is adjustable, and the adjustment range is – 0.1 to 4MPa.

 The controller is made of cast aluminum housing and is waterproof for marine use.

 The controller is a compact design; the non-adjustable controller is available in a small switching difference type.

  • Price Term: FOB/CIF/EXW/DAP
  • Package: Exported Wooden case or according to customer request
  • Delivery Time:  7 to 10 working days
  • Transports: By sea, by air, by high express
  • Shipment Port: Shanghai Port
  • Origin of Place: Jiangsu
  • Warranty: 12 Months
Operating Viscosity <1×10-3m2/s
Service Life 105 times
Ambient Temperature - 25℃ ~55℃
Medium Temperature - 25℃ ~80℃
Vibration Resistance 40m/s2
Repeatability Error ≤1%
Contact Capacity AC 380V 3A (resistive)  AC 220V 6A (resistive)
Withstanding Voltage 150%

Switching Difference Is Not Adjustable

Serial Number Set Value

Adjustment

Range  Mpa

Switching

Difference Is Not Greater  Than  Mpa

Maximum Allowable Pressure

Mpa

Switching times

Times/Min

 

 Sensor Materials
Housing Bellows
1 -0.1~0 0.007 0.5 20 Brass Steel

0Cr17Ni14

Mo2

(316L)

2 0~0.1 0.008
3 0.01~0.25 0.01
4 0.01~0.3 0.01
5 0.02~0.4 0.016 3.0
6 0.03~0.6 0.035
7 0.03~0.8 0.04
8 0.03~1.0 0.04
9 0.03~1.6 0.08 6.0
10 0.05~2.5 0.09
11 0.05~3.0 0.14
12 0.05~4.0 0.2

 

Switching Difference Is Not Adjustable(Small Switching Difference) 

Serial Number Set Value

Adjustment

Range  Mpa

Switching

Difference Is Not Greater  Than  Mpa

Maximum Allowable Pressure

Mpa

Switching times

Times/Min

 

 Sensor Materials
Housing Bellows
1 -0.1~0 0.0045 0.5 20 Brass Steel

0Cr17Ni14

Mo2

(316L)

2 0~0.1 0.0025
3 0.01~0.25 0.01
4 0.01~0.3 0.01
5 0.02~0.4 0.014 3.0
6 0.03~0.6 0.016
7 0.03~0.8 0.02
8 0.03~1.0 0.03
9 0.03~1.6 0.035 6.0
10 0.05~2.5 0.04
11 0.05~3.0 0.05
12 0.05~4.0 0.06

Setting Value Adjustment

See Example 1 and Example 2 for pressure controller setting value adjustment

  1. Do not turn the screws inside the controller to tamper with the internal parts when opening it;
  2. Select the controller so that the predetermined setting value is between 20% and 80% of the controller setting value range;
  3. The switching difference adjustment range in the specification is the guaranteed switching difference provided, the actual range can be slightly wider;
  4. The pressure should not exceed the maximum allowable pressure during commissioning;
  5. The surrounding environment should be free of corrosive gases;
  6. The installation (or disassembly) must use a wrench to hold the sensor part, to absolutely prevent the sensor and the controller case relative rotation To prevent the sensor from rotating relative to the controller body

502/7D-C (Small) Pressure Controller