502/7D,502/7DK Pressure Controller

Features

 The controller uses bellows type sensors for neutral gases such as air, gas, water vapor, and water, refrigerant, oil ,etc. liquid medium .

 The setting value of the controller is adjustable, and the adjustment range is -0.1 to 2.5MPa.

 Can be used for vacuum. For special requirements, the adjustment range of -0.1 to 6.3 MPa can be designed separately.

  • Price Term: FOB/CIF/EXW/DAP
  • Package: Exported Wooden case or according to customer request
  • Delivery Time:  7 to 10 working days
  • Transports: By sea, by air, by high express
  • Shipment Port: Shanghai Port
  • Origin of Place: Jiangsu
  • Warranty: 12 Months
Normal  Type Explosion-proof
Operating Viscosity <1×10-3m2/s <1×10-3m2/s
Switching Element Micro switch Sealed Switches
Explosion Protection Class Exde Ⅱ CT4~T6 Certificate of Conformity No
Enclosure Protection Level IP65(Conforms to DIN40050, equivalent to  IP65 in GB4208) IP54 (Conforms to DIN40050, equivalent to  IP54 in  GB4208)
Ambient Temperature -40℃~50℃ -40℃~50℃
Medium Temperature 0~120℃ 0~120℃
Installation Position Pressure connection vertically down
Anti-Vibration Performance 502/7D:40m/s2 ;502/7DK:20m/s2 Max: 20m/s2
Repeatability Error ≤1% ≤1%
Contact Capacity AC  220V  6A (Resistance) DC 250V  0.25A(Resistance)  60Wmax

AC 250V  5A(Resistance)  1250VAmax

502/7D Switching Difference Is Not Adjustable 

Set Value

Adjustment

Range Mpa

Switching

Difference Is Not Greater Than  Mpa

Maximum Allowable Pressure

Mpa

Switching

 Times

Times/Min

 

Pressure Sensor Materials Interface Female Thread W

Kg

Dimension Drawing
Housing Bellows Normal Ex-Proof
-0.1~0 0.007 1 20 Brass Stainless Steel

00Cr17

Ni14

Mo2

(316L)

G1/4″ 1.0 01 04
-0.1~0.1 0.008
-0.1~0.16 0.009
-0.1~0.25 0.012
0~0.1 0.008
0~0.16 0.009
0.01~0.25 0.01
0.02~0.4 0.03 2 0.85 02 05
0.03~0.6 0.035
0.03~1 0.04
0.05~1.6 0.08 5 0.9 03 06
0.05~2.5 0.09

 

502/7D Switching Difference Is Adjustable

Set Value

Adjustment

Ranga Mpa

Difference Is Not Greater Than  Mpa Maximum Allowable Pressure

Mpa

Switching

Times

Times/Min

 

Pressure Sensor Materials Interface Female Thread W

Kg

Dimension Drawing
Housing Bellows Normal Ex-Proof
-0.1~0 0.019 1 20 Brass Stainless Steel

00Cr17

Ni14

Mo2

(316L)

G1/4″ 1.05 01 04
-0.1~0.1 0.021
-0.1~0.16 0.022
-0.1~0.25 0.024
0~0.1 0.016
0~0.16 0.02
0.01~0.25 0.024
0.02~0.4 0.08 2 0.9 02 05
0.03~0.6 0.09
0.03~1 0.1
0.05~1.6 0.19 5 0.95 03 06
0.05~2.5 0.2

 

 

 

502/7DK Switching Difference Is Not Adjustable (Small Switching Difference,No Explosion-Proof Type)

Set Value

Adjustment

Range  Mpa

Switching

Difference Is Not Greater Than  Mpa

Maximum Allowable Pressure

Mpa

Switching Times

Times/Min

 

Pressure Sensor Materials Interface Female Thread W

Kg

 Dimension Drawing
Housing Bellows
-0.1~0 0.0045 1 20 Brass Stainless Steel

00Cr17

Ni14

Mo2

(316L)

G1/4″ 1.0 01
-0.1~0.1 0.005
-0.1~0.16 0.0065
-0.1~0.25 0.01
0~0.1 0.0045
0~0.16 0.006
0.01~0.25 0.007
0.02~0.4 0.016 2 0.85 02
0.03~0.6 0.02
0.03~1 0.03
0.05~1.6 0.05 5 0.9 03
0.05~2.5 0.06

Note: ① In actual operation, even brief pressure peaks should not exceed this value.

Instructions For Selection And Installation Of Controller

See selection and installation of controller for details

Adjustment Of The Set Value

For details, see the adjustment of the set value of the pressure controller Example I, Example II, Example V

 

Normal  Type

01

Pressure Controller

02

Pressure Controller

03

Pressure Controller

Ex-proof  Type

04

 Explosion-proof Pressure Controller

05

 Explosion-proof Pressure Controller

06

 Explosion-proof Pressure Controller

 

Get Our Best Quotation




    Scroll to Top