 The controller uses a piston type sensor with a drain port for neutral hydraulic oil and other media.

 The setting value of the controller is adjustable, and the adjustment range is from 0.3 to 40MPa.

 Particularly suitable for hydraulic equipment

  • Price Term: FOB/CIF/EXW/DAP
  • Package: Exported Wooden case or according to customer request
  • Delivery Time:  7 to 10 working days
  • Transports: By sea, by air, by high express
  • Shipment Port: Shanghai Port
  • Origin of Place: Jiangsu
  • Warranty: 12 Months
Switching Element Micro switch
 

Enclosure Protection Level

 

IP65(Conforms to DIN40050, equivalent to  IP65 in GB4208)
Ambient Temperature -5℃~50℃
Medium Temperature 0~100℃
Installation Position Pressure connection vertical down (15° tilt allowed)
Anti-Vibration Performance 504/7D: 40m/s2  504/7DK: 20m/s2
Repeatability Error ≤1.5%
 

Contact Capacity

AC  220V  6A (Resistance)

504/7D Switching Difference Is Not Adjustable 

Set Value

Adjustment

Range Mpa

Switching

Difference Is Not Greater Than  Mpa

Maximum Allowable Pressure

Mpa

Switching

Times

Times/Min

Pressure Sensor Materials Interface Female Thread     W

Kg

Dimensions Drawing Number
Housing Piston
0.3~4 0.4 16 30 Galvanized steel Steel G1/4″ 0.9 01
0.3~6.3 0.6
0.5~10 0.9 30
0. 5~16 1.2
1~25 2 80
1~40 2.2

 

504/7D Switching Difference Is Adjustable 

Set Value

Adjustment

Range Mpa

Switching

Difference Is Not Greater Than  Mpa

Maximum Allowable Pressure

Mpa

Switching

Times

Times/Min

 

Pressure Sensor Materials Interface Female Thread    W

Kg

Dimensions Drawing Number
Housing Piston
0.3~4 0.6 16 30 Galvanized steel Steel G1/4″ 0.95 01
0.3~6.3 0.8
0.5~10 1.2 30
0.5~16 1.6
1~25 2.6 80
1~40 3.5

 

504/7DK Switching Difference Is Not Adjustable( Small Switching Difference )

Set Value

Adjustment

Range Mpa

Switching

Difference Is Not Greater Than  Mpa

Maximum Allowable Pressure

Mpa

Switching

Times

Times/Min

Pressure Sensor Materials Interface Female Thread    W

Kg

Dimensions Drawing Number
Housing Piston
0.3~4 0.3 16 30 Galvanized steel Steel G1/4″ 0.9 01
0.3~6.3 0.5
0.5~10 0.7 30
0.5~16 1
1~25 1.5 80
1~40 1.8

Note: ① In actual operation, even brief pressure peaks should not exceed this value.

 

Instructions For Selection And Installation Of Controller

See selection and installation of controller for details

Adjustment Of The Set Value

For details, see the adjustment of the set value of the pressure controller Example 1, Example 2, Example 5

Pressure Controller

Get Our Best Quotation