505/7D Explosion-Proof Pressure Controller

 The controller adopts a non-leakage piston type sensor, which can be used for compressed air containing oil mist and other oil-mist-containing gases with no corrosive effect on the pressure sensor material, and hydraulic oil, water-oil emulsion and neutral liquid media with good lubricating performance.

 For neutral gases containing oil mist

 The set value of the controller is adjustable, and its adjustment range is 0.3 ~ 40MPa.

  • Price Term: FOB/CIF/EXW/DAP
  • Package: Exported Wooden case or according to customer request
  • Delivery Time:  7 to 10 working days
  • Transports: By sea, by air, by high express
  • Shipment Port: Shanghai Port
  • Origin of Place: Jiangsu
  • Warranty: 12 Months
Normal  Type Explosion-proof
Operating Viscosity <1×10-3m2/s <1×10-3m2/s
Switching Element Micro switch Sealed Switches
Explosion Protection Class Exde Ⅱ CT4~T6 Certificate of Conformity No
Enclosure Protection Level IP54 for grooved seals, IP65 for O-rings (according to DIN40050, equivalent to IP65 in GB4208) IP54 for grooved seals, IP65 for O-rings (according to DIN40050, equivalent to IP65 in GB4208)
Ambient Temperature -20℃~40℃ -20℃~40℃
Medium Temperature 0~100℃ 0~120℃
Installation Position Pressure connection vertical down (15° tilt allowed) Pressure connection vertical down (15° tilt allowed)
Anti-Vibration Performance 505/7D: 40m/s2  505/7DK: 20m/s2 Max: 20 m/s2
Repeatability Error ≤2.5% ≤2.5%
Contact Capacity AC  220V  6A (Resistance) DC 250V  0.25A(Resistance)  60Wmax

AC 250V  5A (resistive) 1250  VAmax

505/7D  Switching Difference Is Not Adjustable 

Set Value

Adjustment

Range  Mpa

Switching

Difference Is Not Greater Than  Mpa

Maximum Allowable Pressure

Mpa

Switching Times

Times/Min

 

Pressure Sensor Materials Interface Female Thread    W

Kg

Dimension

Drawing

Housing Seals Piston
0.3~4 0.9 30 20 Brass Nitrile rubber Tape groove Seal ② Steel G1/4 ″ 0.8 01
0.5~6.3 1.3
0.5~10 1.6
0.5~16 1.9
1~23 2.5 30 30 Nitrile O-Ring Seals 02
1~40 2.8 60 30

 

 

505/7D  Switching Difference Is Adjustable

Set Value

Adjustment

Range  Mpa

Switching

Difference Is Not Greater Than  Mpa

Maximum Allowable Pressure

Mpa

Switching Times

Times/Min

Pressure Sensor Materials Interface Female Thread    W

Kg

Dimension

Drawing

Housing Seals Piston
0.3~4 1.3 30 20 Brass Nitrile rubber Tape groove Seal ②

 

Steel G1/4 ″ 0.85 01
0.5~6.3 1.6
0.5~10 1.6
0.5~16 2.2
1~23 2.8 30 30 Nitrile O-Ring Seals 02
1~40 4 60 30

 

505/7DK Switching Difference Is Not Adjustable (Small Switching Difference) 

 

Set Value

Adjustment

Range  Mpa

Switching

Difference Is Not Greater Than  Mpa

Maximum Allowable Pressure

Mpa

Switching Times

Times/Min

Pressure Sensor Materials Interface Female Thread    W

Kg

Dimension

Drawing

Housing Seals Piston
0.3~4 0.8 30 20 Brass Nitrile rubber Tape groove Seal ②

 

 

Steel G1/4 ″ 0.8 01
0.5~6.3 1.2
0.5~10 1.4
0.5~16 1.6
1~23 1.2 30 30 Nitrile O-Ring Seals 02
1~40 1.8 60 30

 

Note: ① In practice, even brief pressure peaks should not exceed this value.

② The slotted seal type should be used to avoid sudden fluctuations in pressure, and if there are sudden fluctuations in pressure, a pressure shock damper should be installed on the interface of the controller.

Adjustment Of The Set Value

See the adjustment of the set value of the pressure controller for details in Example 1, Example 2 and Example 5

Selection And Installation

See selection and installation of the controller for details

01

Pressure controllers

02

Pressure controllers

03

Explosion-Proof Pressure Controller