EJCDP Silicon Resistance Differential Pressure Transmitter Using a digital silicon differential sensor as detecting principle to constitute differential pressure transmitter, inputting pressure is 0~1.2kPa to 0~10MPa, etc. Its best accuracy reaches 0.05% , 0.065%,0.075% etc
- مدة السعر: فوب/سيف/إكسو/إكسو/دباغ
- الحزمة: حقيبة خشبية مصدرة أو حسب طلب العميل
- وقت التسليم:: من 7 إلى 10 أيام عمل
- وسائل النقل: عن طريق البحر، عن طريق الجو، عن طريق البريد السريع
- ميناء الشحن: ميناء شنغهاي
- أصل المكان: جيانغسو
- الضمان: 12 شهرًا
- مقدمة
- المعلمات
- الطراز
- البُعد
- EMC Performance Table
The high-performance differential pressure transmitter EJCDP-A is suitable to measure liquid, gas, or steam flow as well as liquid level, density, and pressure. EJCDP-A outputs a 4~20 mA DC signal corresponding to the measured differential pressure. Its highly accurate and stable sensor can also measure the static pressure which can be shown on the integral indicator or remotely monitored via HART communications. Other key features include quick response, remote set-up using communications, self-diagnostics, and optional status output for pressure high/low alarm.
It is Using differential capacitance as a detecting principle to constitute capacitance type differential pressure transmitter, inputting pressure is 0~1.2kPa to 0~10MPa, etc.
Service medium: liquid, gas, and vapor.
Overpressure limit: impose 0 (absolute pressure) ~6MPa pressure on either side of the transmitter. The transmitter is not damaged. The transmitter’s operation static pressure is detailed in the models and specifications sheet.
● Service: liquid, gas and steam
● Measuring range: 0~0.06 kPa to 0~40Mpa
● Output signal: 4~20mA DC (four-wire 220V AC power supply, 0~10mA DC output for special)
● Power supply: 12~45V DC, generally 24V DC
● Features of loading: relation equation of loading impedance RL and power voltage
Vs: RL <= 50(Vs-12)
● Indicator: pointer-type linearity indication 0~100% scale mark or LCD indicator, LED indicator.
● Explosion proof: a. explosion isolation d II CT6
b. intrinsically safe ia II CT6
● Positive and negative shifts: after positive and negative shifts of zero absolute values of upper-and-lower-limit values of span and measuring range not exceed 100% of upper limit of measuring range.( smart type: turn down ratio 20:1, 40:1)
Maximum positive shift is 500% of minimum adjusting span; maximum negative shift is 600% of minimum adjusting span.
● Temperature range: amplifier operation temperature range: -29 ~ +93C
(LT type: -25 ~ +70C); measuring component of fill silicone oil: -40 ~ +104C
flange type transmitter fill hi-temperature silicone oil: -20 ~ +315C normal silicone oil: -40 ~ +149C
● Static pressure: 4, 10, 25, 32Mpa
● Humidity: relative humidity 0~100%
● Volume absorption: < 0.16cm3
● Damping (phase step response): For silicone oil, generally between 0.2s and1.67s,continuous and adjustable
| جهاز إرسال الضغط التفاضلي EJCDP– | |||||||||||||||||||||||
| 10 | الدقة | ||||||||||||||||||||||
| B | Reference Accuracy±0.075% | ||||||||||||||||||||||
| C | Reference Accuracy±0.1% | ||||||||||||||||||||||
| 20 | الامتداد | ||||||||||||||||||||||
| B | 0-200Pa~6kPa(0-20~600 mmH2O)/(0-2~60mbar) | ||||||||||||||||||||||
| C | 0-400Pa~40kPa(0-40~4000 mmH2O)/(0-20~400mbar) | ||||||||||||||||||||||
| D | 0-2.5kPa~250kPa(0-0.25~25 mH2O)/(0-25~2500mbar) | ||||||||||||||||||||||
| F | 0-30kPa~3MPa(0-3~300 mH2O)/(0-0.3~30bar) | ||||||||||||||||||||||
| 30 | Static pressure sensor | ||||||||||||||||||||||
| 0 | لا يوجد | ||||||||||||||||||||||
| 1 | 40MPa | ||||||||||||||||||||||
| 2 | 10MPa | ||||||||||||||||||||||
| 40 | Diaphragm fill fluid | ||||||||||||||||||||||
| A | فولاذ 316L المقاوم للصدأ | Silicone oil | |||||||||||||||||||||
| B | فولاذ 316L المقاوم للصدأ | Fluorinated oil | |||||||||||||||||||||
| C | هاستيلوي C | Silicone oil | |||||||||||||||||||||
| D | هاستيلوي C | Fluorinated oil | |||||||||||||||||||||
| E | مطلي بالذهب على 316L | Silicone oil | |||||||||||||||||||||
| F | مطلي بالذهب على 316L | Fluorinated oil | |||||||||||||||||||||
| G | FEP plated on 316L | Silicone oil | |||||||||||||||||||||
| T | التنتالوم | Silicone oil | |||||||||||||||||||||
| 50 | ضغط العمل | ||||||||||||||||||||||
| 1 | 16 ميجا باسكال | ||||||||||||||||||||||
| 2 | 25 ميجا باسكال | ||||||||||||||||||||||
| 3 | 40MPa | ||||||||||||||||||||||
| 60 | Process connections | ||||||||||||||||||||||
| N | 7/16-20 UNF and 1/4-18 NPT female thread, No relief valve | ||||||||||||||||||||||
| B | 7/16-20 UNF and 1/4-18 NPT female thread, Relief valves at end of flanges | ||||||||||||||||||||||
| U | 7/16-20 UNF and 1/4-18 NPT female thread, Relief valves at the upper part of
the flange side |
||||||||||||||||||||||
| D | 7/16-20 UNF and 1/4-18 NPT female thread, Relief valve at the lower part of the flange side | ||||||||||||||||||||||
| V | Vertical mounting flange, 7/16-20 UNF and 1/4-18 NPT female thread, Relief valves at the upper part of the flange side | ||||||||||||||||||||||
| L | Level(Low side can select : B/ U/ D) | ||||||||||||||||||||||
| R | Remote Seal | ||||||||||||||||||||||
| 70 | Process connector gasket | ||||||||||||||||||||||
| N | Perbunan(NBR) | ||||||||||||||||||||||
| F | Viton (FKM) | ||||||||||||||||||||||
| P | Teflon (PTFE) | ||||||||||||||||||||||
| 80 | Special function | ||||||||||||||||||||||
| N | لا يوجد | ||||||||||||||||||||||
| F | Square root output | ||||||||||||||||||||||
| O | Degrease cleansing treatment(Oxygen measurement must be with fluorinated oil filled capsule, Viton (FKM) gasket, <6MPa ,<60℃) | ||||||||||||||||||||||
| P | Anti-lightning function | ||||||||||||||||||||||
| 90 | كتيفة التركيب | ||||||||||||||||||||||
| N | لا يوجد | ||||||||||||||||||||||
| 1 | 304 stainless steel | ||||||||||||||||||||||
| 2 | Carbon steel galvanized | ||||||||||||||||||||||
| 100 | Process connector accessory | ||||||||||||||||||||||
| N | لا يوجد | ||||||||||||||||||||||
| 1 | Stainless steel oval-shaped flange with 1/2 NPT female thread | ||||||||||||||||||||||
| 2 | Stainless steel D-shaped connector with M20x1.5 male thread | ||||||||||||||||||||||
| 110 | Integral indicator | ||||||||||||||||||||||
| N | لا يوجد | ||||||||||||||||||||||
| 1 | شاشة LCD | ||||||||||||||||||||||
| 2 | Backlit LCD display | ||||||||||||||||||||||
| 120 | Explosion protected type | ||||||||||||||||||||||
| N | لا يوجد | ||||||||||||||||||||||
| A | Intrinsically safe Approval CNEX ,ExiaIICT6 | ||||||||||||||||||||||
| D | Flameproof Approval CNEX ,Exd IIC T6 | ||||||||||||||||||||||
| B | Intrinsically safe Approval ATEX ,ExiaIICT6 | ||||||||||||||||||||||
| H | Flameproof Approval for ATEX Exd IIC T6 | ||||||||||||||||||||||
| 130 | Tag name plate | ||||||||||||||||||||||
| N | لا يوجد | ||||||||||||||||||||||
| 1 | Position number on the nameplate | ||||||||||||||||||||||
| 2 | Hanging stainless steel plate | ||||||||||||||||||||||
| 140 | Manual | ||||||||||||||||||||||
| C | Chinese | ||||||||||||||||||||||
| E | English | ||||||||||||||||||||||
كيفية الطلب
- النطاق
- متوسط
- ضغط العمل
- درجة حرارة العمل
- Diaphram material
- ضغط العمل
Horizontal Impulse Piping Type(side face) Horizontal Impulse Piping Type(front side)

Horizontal Impulse Wall mounting Type Vertical Impulse Piping Type

| العناصر | Test items | Basic standards | Test conditions | Performance Level |
| 1 | Radiated interference (Housing) | GB/T 9254-2008 | 30MHz~1000MHz | OK |
| 2 | Conducted interference(DC power port) | GB/T 9254-2008 | 0.15MHz~30MHz | OK |
| 3 | Electrostatic Discharge (ESD) Immunity | GB/T 17626.2-2006 | 4kV(Line)
8kV(Air) |
B |
| 4 | RF electromagnetic field immunity | GB/T 17626.3-2006 | 10V/m (80MHz~1GHz) | A |
| 5 | Frequency magnetic field immunity | GB/T 17626.8-2006 | 30A/m | A |
| 6 | Electrical Fast Transient Burst Immunity | GB/T 17626.4-2008 | 2kV(5/50ns,5kHz) | B |
| 7 | Surge Immunity | GB/T 17626.5-2008 | 0.5kV(line to line)
1kV(line to ground)(1.2us/50us) |
B |
| 8 | Conducted interference immunity induced by RF field | GB/T 17626.6-2008 | 3V (150KHz~80MHz) | A |
Note:(1)Performance level A description: The technical specifications within the limits of normal performance.
(2)Performance level B description: Temporary reduction or loss of functionality or performance, it can restore itself. The actual operating conditions, storage, and data will not be changed.