JC 3000B Wall Installed Ultrasonic Flowmeter
Transit-time ultrasonic flow meter is a kind of high accuracy ultrasonic flow meter.
- مقدمة
- المعلمات
- الطراز
- كيفية الطلب
- فيديو
Welcome to use new generation transit-time ultrasonic flow meter, please read the user manual carefully before using. The wall-mount ultrasonic flow meter is designed to be installed in a fixed location for long-term flow measurement.
الميزات
◆ Linearity: 0.5%, Repeatability: 0.2%, Accuracy:±1%
◆ IP67 water & Dust resistant
◆ Several type transducers for selection, measuring pipe size is from DN15mm to DN6000mm
◆ Adopt low voltage, multi-pulse technology to improve accuracy, useful life and reliability.
◆ Powerful Recording Function, record the totalizer data of the last 64 days/64 monthes/5 years.
◆ Three type installation method : wall mounted , DIN-Rain mounted , explosion-proof box mounted
Typical application
The wall-mounting flow meter can be applied to a wide range of pipe flow measurements. Applicable liquids include pure liquids as well as liquid with small quantity of tiny particles.
Examples are:
★ Water (hot water, chilled water, city water, sea water, waste water, etc.);
★ Sewage with small particle content;
★ Oil (crude oil, lubricating oil, diesel oil, fuel oil, etc.);
★ Chemicals (alcohol, acids, etc.);
★ Plant effluent;
★ Beverage, liquid food;
★ Ultra-pure liquids;
★ Solvents and other liquids
| العناصر | المواصفات | |
| Main unit | الدقة | أفضل من ± 1% |
| التكرار | Better than 0.2% | |
| Principle | Transit-time measuring principle | |
| MeasurementPeriod | 500ms | |
| العرض | , velocity, time etc. | |
| المخرجات | Analogue output: 4-20mA or 0-20mA current output. Impedance 0∼1kW. Accuracy 0.1%. | |
| OCT output: Frequency signal (1~9999HZ) | ||
| Relay output: over 20 source signal (no signal, reverse flow etc.) | ||
| RS485 serial port | ||
| المدخلات | Three analogue input | |
| Three-wire PT100 resistor input (optional) | ||
| Other functions | Automatically record the totaliser data of the last 64 days / 64 months / 5 years; The power-on time and corresponding flow rate of the last 64 power on and off events. Allow manual or automatic flow loss compensation The instrument working status of the last 64 days | |
| pipe | المواد | Steel, stainless steel, cast iron, cement pipe, copper, PVC, aluminum, FRP etc. Liner is allowed |
| الحجم | 15-6000mm | |
| Straight pipe section | In the upstream it must be beyond 10D, in the downstream it must be beyond 5D, in the upstream the length must be beyond 30D from the access of the pump. (D stands for pipe diameter) | |
| سائل | Types | Water, sea water, industrial sewage, acid & alkali liquid, alcohol, beer, all kinds of oils which can transmit ultrasonic single uniform liquid |
| درجة الحرارة | Standard: -30˚C – 90˚C ,High-temperature:-30˚C – 160˚C | |
| Turbidity | Less than 10000ppm, with a little bubble | |
| Flow Direction | Bi-directional measuring, net flow/heat measuring | |
| Environment | درجة الحرارة | Main Unit: -30˚C – 80˚C |
| Transducer: -40℃ -110℃, Temperature transducer: select on enquiry | ||
| Humidity | Main Unit: 85% RH | |
| Transducer: water-immersible, water depth less than 3m | ||
| Cable | Twisted Pair Line, standard length of 20m, can be extended to 500m (not recommended); Contact the manufacturer for longer cable requirement.RS-485 interface, transmission distance up to 1000m | |
| مزود الطاقة | AC220V or DC24V | |
| استهلاك الطاقة | Less than 1.5W | |
| Protocols | MODBUS, M-BUS, Fuji extended protocol and other factory protocol | |
لا يوجد

| محولات الطاقة الاختيارية | الطراز | الوصف | نطاق القياس | درجة الحرارة | الدقة |
| محول طاقة صغير الحجم
|
TS-1 | مغناطيسي | DN15-100 مم | -40~90℃ | ±1% |
| محول طاقة متوسط الحجم
|
ت.م.م-1 | مغناطيسي | DN50-1000 مم | -40~90℃ | ±1% |
| محول طاقة كبير الحجم
|
TL-1 | مغناطيسي | DN300-6000 مم | -40~90℃ | ±1% |
| محول طاقة صغير الحجم ذو درجة حرارة عالية الحرارة عالية الحرارة
|
THS-1 | DN15-100 مم | -40~160℃ | ±1% | |
| محول طاقة متوسط الحجم عالي الحرارة متوسط الحجم
|
THM-1 | DN50-1000 مم | -40~160℃ | ±1% |
The wall-mounting flow meter can be applied to a wide range of pipe flow measurements.
Applicable liquids include pure liquids as well as liquid with small quantity of tiny particles.
Examples are:
★ Water (hot water, chilled water, city water, sea water, waste water, etc.);
★ Sewage with small particle content;
★ Oil (crude oil, lubricating oil, diesel oil, fuel oil, etc.);
★ Chemicals (alcohol, acids, etc.);
★ Plant effluent;
★ Beverage, liquid food;
★ Ultra-pure liquids;
★ Solvents and other liquids
Product video