JC-216 LCD Intelligent Temperature Transmitter
The JC-216 LCD intelligent temperature transmitter is used for the input of resistance temperature detector (RTD) signal and thermocouple (TC) signal and two-wire analog signal output (4−20mA).
- Duración del precio: FOB/CIF/EXW/DAP
- Paquete: Exportado Caja de madera o de acuerdo a la petición del cliente
- Plazo de entrega7 a 10 días laborables
- Transportes: Por mar, por aire, por expreso
- Puerto de embarque: Puerto de Shanghai
- Origen del lugar: Jiangsu
- Garantía: 12 meses
- Especificación
- Operations
- Menu settings
- Structure diagram
- Wiring Diagram
Parámetros técnicos
| Entrada | |
| Input Signal | RTD and TC |
| Scope of Cold Junction Compensation Temperature | -20−70℃ |
| Compensation Accuracy | ±1℃ |
| Salida | |
| Output Signal | 4−20mA (The input and output are not isolated.) |
| Load Resistance | RL ≤ (Ue-12)/0.021 |
| Output Current for Upper/Lower Limit Overflow Alarm | IH=21mA and IL=3.8mA |
| Output Current for Input Break Alarm | 21mA |
| Fuente de alimentación | |
| Power Supply Voltage | DC12−40V |
| Other Parameters | |
| Thermal Drift | 0.01%FS/℃ |
| Tiempo de respuesta | 700ms, reaches to 90% of the final value. |
| Environment Temperature | -20−70℃ |
| EMC | Comply with the industry equipment application requirements in GB/T18268 (IEC 61326-1). |
Input Type and Transmission Accuracy:
| Modelo | Symbol | Signal Type | Medición
Scope |
Minimum Measurement Scope | Rang Scope | Transfer Accuracy |
| Resistance Temperature Detector (RTD) | Pt100 | Pt100 | -199.9−850.0℃ | 10℃ | ≤100℃ | 0.2% |
| >100℃ | 0.1% | |||||
| Cu50 | -50.0−150.0℃ | 10℃ | ≤100℃ | 0.2% | ||
| >100℃ | 0.1% | |||||
| Thermocouple (TC) | B | 400−1800℃ | 500℃ | ≤300℃ | 0.2% | |
| >300℃ | 0.1% | |||||
| E | -100−1000℃ | 50℃ | ≤300℃ | 0.2% | ||
| >300℃ | 0.1% | |||||
| J | -100−1200℃ | 50℃ | ≤300℃ | 0.2% | ||
| >300℃ | 0.1% | |||||
| K | -180−1372℃ | 50℃ | ≤300℃ | 0.2% | ||
| >300℃ | 0.1% | |||||
| N | -180−1300℃ | 50℃ | ≤500℃ | 0.2% | ||
| >500℃ | 0.1% | |||||
| R | -50−1768℃ | 500℃ | ≤500℃ | 0.2% | ||
| >500℃ | 0.1% | |||||
| S | -50−1768℃ | 500℃ | ≤500℃ | 0.2% | ||
| >500℃ | 0.1% | |||||
| T | -200−400℃ | 50℃ | ≤500℃ | 0.2% | ||
| >500℃ | 0.1% | |||||
| Wre3-25
(Reserved) |
0—2315℃ | 500℃ | ≤500℃ | 0.2% | ||
| >500℃ | 0.1% | |||||
| Wre5-26
(Reserved) |
0—2310℃ | 500℃ | ≤500℃ | 0.2% | ||
| >500℃ | 0.1% |
NOTE:
- Environment temperature for measuring theabove accuracy is 20℃±2℃.
- The output accuracy “%” is the allowance of the set range scope.
- When measuring the TC, the allowance of cold junction compensation should be considered. The internal allowance of cold junction compensation is smaller than or equal to ±1℃.
Button Descriptions
| Set button (M) | Used for switching among menu parameters. After modifying and saving the menu, press and hold the button back to the measurement value screen. |
| Decrease button (S) | Used for decreasing or modifying the current flickering position. Press and hold the button to move the modification position to the right. |
| Increase button (Z) | Used for increasing or modifying the current flickering position. Press and hold the button to move the modification position to the left. |
In the work status, press and hold the Set button for 5 seconds to display the unlock symbol (LOC); Make LOC=1 and press the Set button to enter the menu. Press the Set button to change parameters and then press the Increase or Decrease button to modify parameter values.
| Symbol | Parámetro | Range Scope | Descripción | Factory Default |
| Loc | 0−50000 | Electronic lock | 0 | |
| Sn | Refer to the input type list. | Sensor type | Pt100 | |
| Unidad | ℃, F, R, K | Temperature unit
℃: Celsius temperature F: Fahrenheit temperature R: Rankine temperature K: thermodynamic temperature |
℃ | |
| Filt | 0−4 | Damping coefficient | 0 | |
| oPL | -199.9−6300.0 | Lower range limit | -199.9 | |
| oPH | -199.9−6300.0 | Upper range limit | 6300.0 | |
| PB | -199.9−200.0 | Measurement value transfer (zero-point) | 0 | |
| PK | 0.0000−1.9999 | Measurement value transfer (gain) | 1.0000 | |
| T-PB | -199.9−200.0 | Modification of cold junction temperature | 0 | |
| Fout | 3.800−21.000 | Fault output current | 21.000 | |
| diR | 0−1 | Current output direction
diR=0: output 4−20mA diR=1: output 20−4mA |
0 | |
| FiX | 0.000−21.000 | Constant current output: if the set value range is less than 3.800−21.000, the output is fixed based on the set value and is independent of the measurement. | 0.000 |