JC-219 Transmisor de temperatura con aislamiento y visualización en campo
JC-219 field display isolation temperature transmitter is used for RTD, thermocouple (TC), resistance (Ω), voltage (mV) signal input, two-wire system 4-20mA analog output, and the configuration is via RS485 (MODBUS RTU protocol) or HART protocol.
- Duración del precio: FOB/CIF/EXW/DAP
- Paquete: Exportado Caja de madera o de acuerdo a la petición del cliente
- Plazo de entrega7 a 10 días laborables
- Transportes: Por mar, por aire, por expreso
- Puerto de embarque: Puerto de Shanghai
- Origen del lugar: Jiangsu
- Garantía: 12 meses
- Especificación
- Instrument selection
- Structural profile
- Wiring diagram
Parámetros técnicos
| Entrada | |
| Input signal | RTD, thermocouple, resistance (Ω) |
| Cold-end compensation temperature range | -20~60℃ |
| Compensation accuracy | ±1℃ |
| Salida | |
| Señal de salida | 4~20mA, or 4~20mA plus HART protocol |
| Load resistance | RL≤(Ue-12)/0.022 |
| Overflow alarm output current at the upper and lower limits | IH=21mA, IL=3.8mA |
| Input disconnection alarming output current | it can be set. |
| Power source | |
| Power supply voltage | DC12~40V |
| Other parameters | |
| Transmission accuracy (20℃) | 0.1%FS |
| Temperature drift | 0.0075%FS/℃ |
| Tiempo de respuesta | 700ms reaches 90% of the final value. |
| Ambient temperature in use | -40~80℃ |
| Temperatura de almacenamiento | -40~100℃ |
| Insulation strength (between input and output) | 1500Vrms(1min, no sparkle) |
| Insulation resistance (between input and output) | ≥100MΩ (at 500VDC) |
| Protection level | IP65, Dustproof, waterproof |
| Connection mode | M20*1.5 Internal thread |
| Electromagnetic compatibility | In compliance with GB/T 18268 Industrial Equipment Application Requirements (IEC 61326-1). |
Input type list:
| Modelo | Tipo | Measurement range | Minimum measurement range |
| RTD | Pt100 | -200~850℃ | 10℃ |
| Cu50, Cu100 | -50~150℃ | 10℃ | |
| Resistance signals(Ω) | Resistance sensor | 0~4000Ω | 10Ω |
| Thermocouple (TC) | B | 400~1820℃ | 500℃ |
| E | -270~1000℃ | 50℃ | |
| J | -210~1200℃ | 50℃ | |
| K | -270~1372℃ | 50℃ | |
| N | -270~1300℃ | 50℃ | |
| R | -50~1768℃ | 500℃ | |
| S | -50~1768℃ | 500℃ | |
| T | -270~400℃ | 50℃ |
| JC219 | 00 | No Communication |
| 01 | RS485 communication | |
| 02 | Hart Communication | |
| 03 | 2088 housing | |
| 04 | 644 housing | |
| 05 | Explosion-proof SS cable entry | |
| 06 | Plastic Waterproof cable entry | |
2088 housing

644 housing


Obtenga nuestro mejor presupuesto