Transmisor de nivel de presión diferencial EJCLT
EJCLT differential pressure level transmitter is suitable to measure liquid, gas, or steam flow as well as liquid level, density and pressure.
- Introducción
- Parámetros
- Modelo
- Cómo hacer un pedido
- Vídeo
EJCLT differential pressure level transmitter
EJCLT differential pressure level transmitter is suitable to measure liquid, gas, or steam flow as well as liquid level, density and pressure. outputs a 4 to 20 mA DC signal corresponding to the measured differential pressure. Its highly accurate and stable sensor can also measure the static pressure which can be shown on the integral indicator or remotely monitored via HART communications. Other key features include quick response, remote set-up using communications, self-diagnostics and optional status output for pressure high/low alarm. The range Limits is 0—1kPa~2MPa, The flange’s working pressure are 1.6/4MPa,6.4MPa,10MPa,150psi,300psi or 600psi.
Teoría y estructura del funcionamiento
Differential pressure level transmitter is composed of series differential pressure transmitter and the welding installation level flange. The operation theory is the same as series differential pressure transmitter (look series differential pressure transmitter general specifications), Only the high pressure side of pressure transmission path is different.The pressure Loaded in the high side, pass from the isolation diaphragm and silicone oil in the flange to the sensor.

Technical Parameter for EJCLT Differential Pressure Level Transmitter
Entrada
Measured value: Differential pressure, Level
Rango de medición
Lower range value: -100% to +100% of the
Salida
Señal de salida
Two wire 4 to 20 mA DC output with digital communications, linear or square root programmable. HART FSK protocol are superimposed on the 4 to 20 mA signal. Output range: 3.9 mA to 20.5 mA.
Failure Alarm (the mode can be selected)
Low Mode (min): 3.7 mA, High Mode (max): 21 mA
No Mode (hold): Keep the effective value before the fault. Note: The standard setting of failure alarm is High Mode.
Tiempo de respuesta
The amplifier damping constant is 0.1 sec; The sensor and flange’s damping constant is 0.2~3 sec, it depends on the range and range compression ratio. Amplifier damping time constant is adjustable from 0.1 to 60 sec by software and added to response time.
Model Selection for EJCLT Differential Pressure Level Transmitter
| Dispositivo de sellado de bridas | ||
| Dispositivo de sellado de bridas | ||
| EJC | LT | Level flange sealing , no capillary |
| Process connection, Flange and diafragma material | ||
| A | DN50 DIN 2501 | E DN2526 Acero inoxidable 316L |
| B | DN50 DIN 2501 | E DN2526 Hastelloy C |
| C | DN50 DIN 2501 | E DN2526 Tántalo |
| H | DN80 DIN 2501 | E DN2526 Acero inoxidable 316L |
| I | DN80 DIN 2501 | E DN2526 Hastelloy C |
| G | DN80 DIN 2501 | E DN2526 Tántalo |
| D | DN2″ANSI B 16,5 | RF ANSI B 16.5 Acero inoxidable 316L |
| E | DN2″ANSI B 16,5 | RF ANSI B 16.5 Hastelloy C |
| F | DN2″ANSI B 16,5 | RF ANSI B 16.5 Tántalo |
| K | DN3″ANSI B 16,5 | RF ANSI B 16.5 Acero inoxidable 316L |
| L | DN3″ANSI B 16,5 | RF ANSI B 16.5 Hastelloy C |
| M | DN3″ANSI B 16,5 | RF ANSI B 16.5 Tántalo |
| N | DN4″ANSI B 16,5 | RF ANSI B 16.5 Acero inoxidable 316L |
| O | DN4″ANSI B 16,5 | RF ANSI B 16.5 Hastelloy C |
| P | DN4″ANSI B 16,5 | RF ANSI B 16.5 Tántalo |
| Presión de trabajo | ||
| 1 | PN 1MPa/4MPa | DIN 2501 |
| 2 | PN 6,4MPa | DIN 2501 |
| 3 | PN 10MPa | DIN 2501 |
| 6 | 150 psi | ANSI B 16.5 |
| 7 | 300 psi | ANSI B 16.5 |
| 8 | 600 psi | ANSI B 16.5(no incluye DN4″ANSI B 16.5 |
| Conexiones de proceso | ||
| F | Sellado plano | |
| H | Bulge sealing 316L stainless steel,extended diaphragm seal 50mm | |
| I | Bulge sealing 316L stainless steel,extended diaphragm seal 100mm | |
| G | Bulge sealing 316L stainless steel,extended diaphragm seal 150mm | |
| L | Obturación de bulto Hastelloy C, junta de membrana prolongada 50mm | |
| M | Obturación de bulto Hastelloy C, junta de diafragma prolongada 100mm | |
| N | Obturación de bulto Hastelloy C, junta de diafragma ampliada 150mm | |
| Llenar líquido | ||
| S | Aceite de silicona -30-200 °C | |
| V | Aceite vegetal 0-250°C | |
| Protección del diafragma | ||
| N | Ninguno | |
| 1 | EFP plated on 316L, ≤180°C | |
| 2 | PFA plated on 316L, ≤260°C | |
| 3 | PTFE coated on 316L[2], ≤200°C | |
- How to order EJCLT differential pressure level transmitter
- Medio
- Gama
- Flange size ,rating and standard
- Precisión
- Otros requisitos