JC010 Medidor de flujo de gas másico térmico de tamaño pequeño
JC010 Small Size Thermal Mass Gas Flowmeter is designed on the basis of thermal dispersion, and adopts method of constant differential temperature to measuring gas flow. It has advantages of small size, easy installation, high reliability and high accuracy, etc.
- Duración del precio: FOB/CIF/EXW/DAP
- Paquete: Exportado Caja de madera o de acuerdo a la petición del cliente
- Plazo de entrega7 a 10 días laborables
- Transportes: Por mar, por aire, por expreso
- Puerto de embarque: Puerto de Shanghai
- Origen del lugar: Jiangsu
- Garantía: 12 meses
- Introducción
- Característica
- Parámetros
- Dimensión
- Cómo hacer un pedido
- Instalación
- Embalaje
JC010 Medidor de flujo de gas másico térmico de tamaño pequeño

The JC010 thermal gas mass flow meter is designed on the basis of thermal dispersion and adopts the method of constant differential temperature to measuring gas flow. It has advantages of small size, easy installation, high reliability, and high accuracy, etc.
The meter contains two platinum resistance temperature sensors. The thermal principle operates by monitoring the cooling effect of a gas stream as it passes over a heated sensor. Gas flowing through the sensing section passes over two sensors one of which is used conventionally as a temperature sensor, whilst the other is used as a heater. The temperature sensor monitors the actual process values whilst the heater is maintained at a constant differential temperature above this by varying the power consumed by the sensor. The greater the gas velocity, the greater the cooling effect and power required to maintain the differential temperature. The measured heater power is therefore a measure of the gas mass flow rate.
Feature for JC010 Small Size Thermal Mass Gas Flowmeter
- Measuring the mass flow or volume flow of gas
- Do not need to do temperature and pressure compensation in principle with accurate measurement and easy operation.
- Wide range: 0.5Nm/s~100Nm/s for gas. The meter also can be used for gas leak detection
- Good vibration resistance and long service life. No moving parts and pressure sensor in the transducer, no vibration influence on the measurement accuracy.
- Easy installation and maintenance. If the conditions on site are permissible, the meter can achieve a hot-tapped installation and maintenance. (Special order of custom-made)
- Digital design, high accuracy, and stability
- Configuring with RS485 or HART interface to realize factory automation and integration

Technical Parameter for JC010 Small Size Thermal Mass Gas Flowmeter
| Descripción | Especificaciones |
| Medio de medición | Various gases (except the acetylene ) |
| Tamaño del tubo | DN3 to DN10 |
| Velocidad | 0.1 to 100Nm/s |
| Precisión | ±1 to 2.5 % |
| Temperatura de trabajo | Sensor :-40 to 220 °C
Transmitter :-20 to 45 °C |
| Presión de trabajo | Insertion sensor : medium pressure ≤1.6Mpa
Flange sensor :medium pressure ≤1.6Mpa Special pressure confirm us |
| Alimentación | 24 VDC |
| Tiempo de respuesta | 1 S |
| Salida | 4-20ma ( Optoelectronix isolation , maximum load 500 ,pulse , RS 485 |
| Alarm Output | 2 line relay , normally open state , 3A/30VDC |
| Sensor type | Standard insertion , hot-tapped insertion and flanged |
| Construction | Compact and remote |
| Pipe Material | Carbon steel , stainless steel , plastic , etc |
| Mostrar | 4 lines LCD
Mass flow , volume flow in standard condition , flow totalizer , velocity |
| Clase de protección | IP 65 |
| Sensor Housing Material | Stainless steel 316 |

Cómo hacer un pedido
- Tamaño del tubo
- Medio
- Caudal
- Alimentación
- Working pressure and temperature
- Conexión a proceso












