JC091 Caudalímetro electromagnético de inserción compacto

JC091 insertion electromagnetic flowmeter is a new fluid flowmeter developed based on a pipe-type electromagnetic flowmeter. It is suitable for large pipe sizes with low cost.

  • Duración del precio: FOB/CIF/EXW/DAP
  • Paquete: Exportado Caja de madera o de acuerdo a la petición del cliente
  • Plazo de entrega7 a 10 días laborables
  • Transportes: Por mar, por aire, por expreso
  • Puerto de embarque: Puerto de Shanghai
  • Origen del lugar: Jiangsu
  • Garantía: 12 meses

JC091 insertion electromagnetic flowmeter is a new fluid flowmeter developed based on a pipe-type electromagnetic flowmeter. Besides preserving the merits of the pipe-type electromagnetic flowmeter and considering such defects of pipe-type electromagnetic flowmeter as difficult installation on large pipes and high cost, JC091 flowmeter measures mean fluid flow rate in the electromagnetic method according to NIKURADS principle, so as to obtain the fluid volume flow. In particular, after technologies of hot tapping and installation under pressure are applied, the insertion electromagnetic flowmeter can be installed without conducting shutdown or cutting off the water supply as well as on cast iron pipe or cement pipe. The successful development of the insertion electromagnetic flowmeter provides a new means for inspection of fluid flow.

Compared to an ordinary electromagnetic flowmeter, the sensor of insertion electromagnetic flowmeter generates an external emission magnetic field on the outer side. The measuring electrodes are at the ends or on both sides of the sensor. The principle of the electromagnetic flowmeter is shown in the figure below. It is noteworthy that in the external emission magnetic field, the induction signal of the electromagnetic flow sensor will reduce the linearity of measurement in case of being affected by fluid and thickness of the magnetic field’s boundary layer.

In terms of the JC091 insertion electromagnetic flowmeter, conducting liquid in the pipeline is the conductor moving in the magnetic field, and the distance between two electrodes is the length (L) of the conductor.

 

 

JC091

Power:24 VDC or 220 VAC

  

 

Caudalímetro electromagnético insertado Caudalímetro electromagnético remoto
Compact  type Remote control  type
 

JC091

Power: Battery type

Caudalímetro electromagnético de inserción Caudalímetro electromagnético a pilas
With a built-in  pressure sensor IP 68
Precisión ±0.5%~±1.5% (under reference conditions)
Caliber (mm) DN100~DN3000 DN100~DN3000
Brida Conforming to GB9119, stainless steel
Pressure rating 1,6MPa
Material of converter housing Die-cast aluminum alloy
Material of sensor housing Acero inoxidable
Material of sensor structure Stainless steel/PVDF
Peso 6 kg
Electrical conductivity ≥5μs/cm (negotiate with us for ordering in case of less than 5μs/cm)
Electrode  316L, Hastelloy, titanium, tantalum, and platinum
Protection grade IP65 IP65/IP67(IP68 is optional to the sensor)
Temperatura media -25℃~80℃ -25℃~120℃
Temperatura ambiente -25℃~60℃
Effect of ambient temperature <±0.1%/10℃ or <±0.25%/10℃
Repetitiveness ≤±0.01% or ≤±0.25%
Analog output error ≤±0.02mA
Flow rate within measuring range ≤10m/s
Available to be buried — ≤5m (only IP68)
Electrical connection M20*1.5 seals, G1/2 and NPT1/2
Sensor cable <30M (negotiate with us for ordering in case of over length)
Código Diámetro nominal

(mm)

Caudal

(m3/h)

Código Diámetro nominal (mm) Caudal

(m3/h)

JC091-100

JC091-125

JC091-150

JC091-200

JC091-250

JC091-300

JC091-350

JC091-400

JC091-450

JC091-500

JC091-600

JC091-700

JC091-800

JC091-900

JC091-1000

DN100

DN125

DN150

DN200

DN250

DN300

DN350

DN400

DN-450

DN-500

DN-600

DN-700

DN-800

DN-900

DN-1000

8.48~282.6

13.25~441.56

19.08~635.85

33.91~1130.40

52.99~1766.25

76.30~2543.40

103.86~3461.85

135.65~4521.60

171.00~5722.65

211.95~7065.00

305.21~10173.00

415.42~13847.40

542.59~18086.40

686.72~22890.60

847.80~28260.00

JC091-1200

JC091-1400

JC091-1600

JC091-1800

JC091-2000

JC091-2200

JC091-2400

JC091-2600

DN-1200

DN-1400

DN-1600

DN-1800

DN-2000

DN-2200

DN-2400

DN-2600

1220.83~40694.40

1661.69~55389.60

2170.37~72345.60

2746.87 ~91562.40

3391.20~113040.00

4103.35~136778.40

4883.33~162777.60

5731.13~191037.60

Código Material del electrodo
K1

K2

K3

K4

K5

K6

K7

SS 316L

Hastelloy B

Hastelloy C

Titanio

Tántalo

Aleación de Pt/Iridio

Pintura de acero inoxidable Carburo de tungsteno

Código Material de la camisa
C1 PVDF
Código Función
E1

E2

E3

F1

F2

F3

F4

T1

T2

T3

P1

P2

P3

P4

P0

D1

D2

D3

J1

J2

J3

J4

Class 1.5%

Clase 1.0%

Class 2.5%

4~20mADC, carga ≤750Ω

0~3kHz, 5V activo, pulso cambiable, terminal alto y salida de frecuencia efectiva

Interfaz RS 485 (Modbus)

HART

Temperatura normal

Alta temperatura

Ultra Temperatura

1,0MPa

1,6MPa

4,0MPa

16MPa

Presión especial

220VAC+10%; 50Hz+ 1Hz

24VDC+10%

Funciona con pilas

Tipo integral

Tipo remoto

A prueba de explosiones

With built-in pressure sensor

JC091 Compact Insertion Electromagnetic Flowmeter-1

Installation-JC091 Compact Insertion Electromagnetic Flowmeter-2

 

Installation-JC091 Compact Insertion Electromagnetic Flowmeter