JC091 Caudalímetro electromagnético de pila de inserción

JC091 Insertion Battery Electromagnetic Flowmeter is a new fluid flowmeter developed based on pipe-type electromagnetic flowmeter. Besides preserving the merits of pipe-type electromagnetic flowmeter and considering such defects of pipe-type electromagnetic flowmeter as difficult installation on large pipes and high cost.

JC091 Insertion Battery  Electromagnetic Flowmeter 

JC091 Insertion battery Electromagnetic Flowmeter is  a new fluid flowmeter developed based on pipe-type electromagnetic flowmeter. Besides preserving the merits of pipe-type electromagnetic flowmeter and considering such defects of pipe-type electromagnetic flowmeter as difficult installation on large pipes and high cost.

Compared to ordinary electromagnetic flowmeter, sensor of insertion electromagnetic flowmeter generates external emission magnetic field on outer side. The measuring electrodes are at the ends or on both sides of the sensor. Principle of electromagnetic flowmeter is shown in the figure below. It is noteworthy that in external emission magnetic field, the induction signal of electromagnetic flow sensor will reduce the linearity of measurement in case of being affected by fluid and thickness of the magnetic field’s boundary layer.

In terms of JC091 insertion electromagnetic flowmeter, conducting liquid in pipeline is the conductor moving in magnetic field and distance between two electrodes is the length (L) of conductor.

insertion-magnetic-flowmeter-1.jpginsertion-magnetic-flowmeter-1.jpg

Technical Parameter for JC091 Insertion Battery Electromagnetic Flowmeter 

 

JC091

Power :24 VDC or 220 VAC

  

 

inserted-type -electromagnetic-flowmeter.jpg 主图1.jpg
Compact  type Remote control  type
 

JC091

Power :Battery type

主图1.jpg 主图1.jpg
With built in  pressure sensor IP 68
Precisión ±0.5%~±1.5% (under reference conditions)
Caliber (mm) DN100~DN3000 DN100~DN3000
Brida Conforming to GB9119, stainless steel
Pressure rating 1,6MPa
Material of converter housing Die-cast aluminum alloy
Material of sensor housing Acero inoxidable
Material of sensor structure Stainless steel/PVDF
Peso 6 kg
Electrical conductivity ≥5μs/cm (negotiate with us for ordering in case of less than 5μs/cm)
Electrode  316L, hastelloy, titanium, tantalum and platinum
Protection grade IP65 IP65/IP67(IP68 is optional to sensor)
Temperatura media -25℃~80℃ -25℃~120℃
Temperatura ambiente -25℃~60℃
Effect of ambient temperature <±0.1%/10℃ or <±0.25%/10℃
Repetitiveness ≤±0.01% or ≤±0.25%
Analog output error ≤±0.02mA
Flow rate within measuring range ≤10m/s
Available to be buried — ≤5m (only IP68)
Electrical connection M20*1.5 seal, G1/2 and NPT1/2
Sensor cable <30M (negotiate with us for ordering in case of over length)

Model Selection for JC091 Insertion Remote Electromagnetic Flowmeter

Código Diámetro nominal

(mm)

Caudal

(m3/h)

Código Diámetro nominal (mm) Caudal

(m3/h)

JC091-100

JC091-125

JC091-150

JC091-200

JC091-250

JC091-300

JC091-350

JC091-400

JC091-450

JC091-500

JC091-600

JC091-700

JC091-800

JC091-900

JC091-1000

DN100

DN125

DN150

DN200

DN250

DN300

DN350

DN400

DN-450

DN-500

DN-600

DN-700

DN-800

DN-900

DN-1000

8.48~282.6

13.25~441.56

19.08~635.85

33.91~1130.40

52.99~1766.25

76.30~2543.40

103.86~3461.85

135.65~4521.60

171.00~5722.65

211.95~7065.00

305.21~10173.00

415.42~13847.40

542.59~18086.40

686.72~22890.60

847.80~28260.00

JC091-1200

JC091-1400

JC091-1600

JC091-1800

JC091-2000

JC091-2200

JC091-2400

JC091-2600

DN-1200

DN-1400

DN-1600

DN-1800

DN-2000

DN-2200

DN-2400

DN-2600

1220.83~40694.40

1661.69~55389.60

2170.37~72345.60

2746.87 ~91562.40

3391.20~113040.00

4103.35~136778.40

4883.33~162777.60

5731.13~191037.60

Código Material del electrodo
K1

K2

K3

K4

K5

K6

K7

SS 316L

Hastelloy B

Hastelloy C

Titanio

Tántalo

Aleación de Pt/Iridio

Pintura de acero inoxidable Carburo de tungsteno

Código Material de la camisa
C1 PVDF

 

Código Función
E1

E2

E3

F1

F2

 

F3

F4

T1

T2

T3

P1

P2

P3

P4

P0

D1

D2

D3

J1

J2

J3

J4

Class 1.5%

Clase 1.0%

Class 2.5%

4~20mADC, carga ≤750Ω

0~3kHz, 5V activo, pulso cambiable, terminal alto y salida de frecuencia efectiva

Interfaz RS 485 (Modbus)

HART

Temperatura normal

Alta temperatura

Ultra Temperatura

1,0MPa

1,6MPa

4,0MPa

16MPa

Presión especial

220VAC+10%; 50Hz+ 1Hz

24VDC+10%

Funciona con pilas

Tipo integral

Tipo remoto

A prueba de explosiones

With built-in pressure sensor

How to order JC091 Insertion Remote Electromagnetic Flowmeter

  1. Medio
  2. Tamaño del tubo
  3. Presión de trabajo
  4. Temperatura de trabajo
  5. Alimentación
  6. Otros requisitos

Productos relacionados