Transmisor multivariable JCMC con Hart

Consists of a differential pressure sensor module with integrated electronic adapter unit, an amplifier module with a control unit and a two-wire system RTD input terminal to measure process temperature.

JCMC Multivariable Transmitter with hart

The  transmitter  adopts  modularized  design.  It  consists  of  a  differential  pressure  sensor  module  with integrated electronic adapter unit, an amplifier module with a control unit and a two-wire system RTD input terminal to measure process temperature. The sensor module adopts full-welded structure, interior of which is a twin-barrel system with an intact overload isolation diaphragm, and one absolute pressure sensor and one differential pressure sensor are installed inside. The absolute pressure sensor is only installed on the high-pressure  side,  and  the  measured  pressure  will  be  taken  as  reference  value,  in  order  to  compensate influence from static pressure. The differential pressure sensor is made up of one capillary tube connected with negative pole of the sensor module.

An additional differential pressure (Dp) will be applied onto diaphragm of the differential pressure sensor through the isolation diaphragm and filler liquid. Check for tiny variation of the diaphragm, which shall result in changes of output voltage of the testing system. The voltage signal direct proportional to the input pressure will be digitalized through the adapter before being transmitted  into  the  amplifier,  and  then  the  amplifier  will  perform  linearization  on  the  signal  as  well  as temperature compensation. Then, three values of Dp, P and T can be converted signals direct proportional to mass flowrate through compensation. Except for mass flowrate (Qm), Dp, P, T and Qv can also make for other purpose of application. According  to  differences  of  transmitter  models,  connection  between  the transmitter  and  process  can  be  fulfilled  through  female  screw  on  elliptic  flange  on  the  transmitter,  or connection between remote flanges and process pipelines or flanges.

The transmitter adopts a two-wire system, the same pair of leads in which can be used to connect working voltage,  signal  outputs  (4~20mA)  and  digital  quantities.  Electrical connection can be fulfilled through interconnection with terminals through cable inlet.

 

ESPECIFICACIONES DE RENDIMIENTO

Reference Accuracy of Calibrated Span (includes

terminal-based linearity, hysteresis, and repeatability)

± 0.1%/± 0.01%

If TD>10 (TD=URL/SPAN):

±(0.0075×TD)%/ ±(0.01×TD)%

Efectos de la temperatura ambiente

-20℃~65℃:±(0.15×TD+0.05)%×Span

Every 10℃ is ±0.08% ×Span (TD=1)

-40℃~-20℃ & 65℃~85℃:

±(0.2×TD+0.05)%×Span

Efectos de la presión estática

±(0.05%URL+0.075%Span)/10MPa

Overpressure Effects: ±0.1%×Span /10MPa。

Stability: ±0.1%×Span /3 years

Efectos de la fuente de alimentación

±0,001% /10V (12~42V CC)

Medición de la temperatura

-50℃~650℃

Límites de ajuste a cero

Zero can be fully elevated or suppressed, within the

lower and upper range limits of the capsule.

Ajuste a cero externo

External zero is continuously adjustable with 0.01%

incremental resolution of span. Re-range can be done

locally using the range setting switch.

Sample
 

JCMT

 

JCMT Multivariable Pressure Transmitter

 

Salida

 

H

Two wire 4-20ma DC ( Hart ) M
 

M

Three wire 4-20ma DC Output: flow rate
 

Sensor

 

Presión diferencial

Compound Micro-Silicon Sensor Capacitance Sensor  

B

 

A

0-50pa to 1pa (Rated pressure is 0.6mpa)  

2E

0 to 1.5Kpa
 

B

0 – 200pa to 6 kpa  

3E

0 to 7.5kpa
 

C

0 -400pa to 40kpa  

4E

0 to 37.4 kpa
 

D

0-2.5kpa to 250 kpa  

5E

0 to 186 kpa
 

Gauge

Presión

 

No

 

No

Rated pressure compensated  

 

4

 

N1

0 -3.5 Mpa
 

N2

0-7Mpa
 

N3

0-40Mpa
 

NS

0.6Mpa ( only for DP A )
 

Medium Temp

 

T0

Rated valve temperature compensated  

T1

 

T1

Pt 100 ( Hart flow rate is Pt 1000)
 

Caudal

 

Calculation

 

Measured Medium

 

1

 

2

 

3

 

4

 

5

 

6

 

7

 

8

 

9

 

6  

Air Stack Gas Coal gas Natrual Gas Heated Steam Saturation Steam Compressed Gas Líquido Otros
 

Pipe Size

DNxx XX ,mm DN50
 

Throttling element Type

 

K

Throttling element  don’t need calibrate , such as Orifice Plate,Nozzle ,Venturi  

 

K

 

S

Linear orifice plate
 

V

Calibrated throttling element ,such as V-cone
 

J

Inserted averaging pitot-tube
 

F

Other non-standard throttling element
 

 

Accesorios

 

 

 

 

 

 

Conexión a proceso

 

C

Without Process connecttor , 1/4 to 18NPT female td C0
 

C1

With 1/2-14 NPT female thread
 

C2

M 20 *1.5 T shape connector + welded pipe
 

T

With three way manifold
 

Accesorios

 

Differential pressure Sensor

 

diafragma

 

Diaphram

 

Diaphram

 

Fill oil

 

E

316L Silicon oil
 

F

316L Fluorocarbon oil(explosion-proof) E
 

A

HC Silicon oil
 

B

HC Fluorocarbon oil(explosion-proof)
 

 

 

Accesorios

 

Mostrar

 

M0

Without display and magnetic pen

 

M1
 

M1

Dot-matrix LCD display and Magnetic pen

 

 

Entrada de cables

 

D

NPT 1/2 N thread E
 

E

M20*1.5 Cable airproof
 

 

Installation Yoke

 

B0

Without installation Yoke  

B0

 

B1

Bend Mounting Yoke for pipe
 

B2

Bend mounting yoke for Plate
 

B3

Flat Mounting Yoke
 

 

 

 

 

Otros

 

A prueba de explosiones

 

E0

Normal ,without explosionproof  

E0

 

E1

Intrinsically Safe ExibIICT 5
 

E2

A prueba de explosiones
 

Measurement Function ( Modbus)

 

A

Compound sensor ( Differential pressure , Gauge Pressure , medium  temperature ) , three way 4-20ma output  

B

 

B

Mass flow rate function( Instant flow rate , gauge pressure , medium temperature) three way 4-20ma output
Model Selection :JCMT10TC-M-BN1T1-6DN50K-C0M1EBO-E0B
  1. How to order JCMC Multivariable Transmitter with hart
  2. Medio
  3. Gama
  4. Presión de trabajo
  5. Temperatura de trabajo
  6. Process connection :flange size , rating  capillary length
  7. Otros requisitos