Medidor de flujo de gas másico térmico JC010

JC010 Thermal Mass Gas Flow Meter can measure the mass and volume flow rate of gas without humidity and pressure compensation.

  • Duración del precio: FOB/CIF/EXW/DAP
  • Paquete: Exportado Caja de madera o de acuerdo a la petición del cliente
  • Plazo de entrega7 a 10 días laborables
  • Transportes: Por mar, por aire, por expreso
  • Puerto de embarque: Puerto de Shanghai
  • Origen del lugar: Jiangsu
  • Garantía: 12 meses

The working principle of JC010 Thermal Mass Gas Flow Meter is that a fluid flowing past a heated temperature sensor removes a known quantity of heat as it passes. In a thermal flowmeter, the fluid has to pass two temperature sensors. One sensor obtains a reference value by measuring the actual process temperature. The second sensor is a heating element and it receives precisely as much energy as is needed to compensate for dispersed heat and maintain a precisely defined temperature difference.

Cuanto mayor es el caudal másico que pasa por el sensor de temperatura calentado, más calor se disipa y más potencia hay que suministrar al elemento para mantener la diferencia de temperatura.

The heating current, therefore, is a measure of the mass flow of the gas.

Due to the sensor temperature is always 30℃ higher than the medium temperature (environment temperature), and the meter adopts the method of constant differential temperature, therefore the meter does not need to do temperature and pressure compensation in principle.

Introduction-thermal mass flowmeter 1

Dimension-thermal mass fowmeter

  • Measure mass flow, no need for humidity and pressure compensation.
  • Large rangeability, flow velocity: 0.1 Nm/s~100Nm/s.
  • No pressure drops, applicable to any section pipe.
  •  Anti-corrosion, applicable to corrosive gas.
  • Online installation and maintenance.
  • Measures mass flow directly – without additional pressure and temperature inputs
  • Accurate measurement and operation at very low gas pressures and flow rates
  • Negligible pressure drop

Thermal-mass-flow-meter-introduction

Tipo de inserto Tipo de tubo
Medio Gas único (excepto gas acetileno) o gas mixto de fijo
Tamaño del tubo DN80-6000 mm DN15-2000mm
Velocidad 0.1Nm/s~100Nm/s ( standard working condition 20 ℃101.33Kpa)
Precisión +1%
Temperatura media -40~200℃
Presión 2,5Mpa 4,0Mpa
Alimentación AC220V o DC24V para convertidor integral y AC220V para convertidor partido.
Tiempo de respuesta ≦1s
Salida de señal 4~20mA RS-485,Modbus
Mostrar Instantaneous flow, mass flow, volume flow, cumulative flow, Beijing time, running time.
Código IP del sensor IP68
Convertidor Código IP IP67 for integral typeIP 65 for split hanging typeIP 52 for split box type
Degradación a prueba de explosiones Exd IΙ CT 4
Código Descripción Observación
JC010 Caudalímetro másico de gas térmico
Dn15, Dn20 …. Diámetro :DN15 a 6000
F Tipo integral en línea Estructura
I Tipo en línea separada
PI Tipo integral de inserción
PL Tipo de inserción separada
T Roscado, como 1/2″NPT Conexión
F Brida , como 2″,ANSI
W Asiento soldado
B Asiento soldado + válvula de bola
A0 Sin protección contra explosiones A prueba de explosiones
A1 A prueba de explosiones
T1 -20 a 150 °C Estándar Temperatura de trabajo
T2 -20 a 200 °C Alta temperatura
P0 Presión negativa Presión de trabajo
P1 0-1,0Mpa
P2 0-.1.6 Mpa
P3 0-2,0 Mpa
P4 0-3,0Mpa
D 24 VDC Alimentación
A 220 VAC
O Otros
0 Ninguno Salida de señal
1 4-20ma
2 RS 485
3 4-20ma + Hart
L Con LCD Mostrar
O Sin LCD
B 316SS Material del sensor  
L HC
C Ti
O Otros

1.Medium

2.Pipe size

3.Flow rate (min/normal/max)

4.Working temperature

5.Working pressure

6.Process connection

7.Power supply

8.Other special requirement

Application-thermal mass flowmeter

Productos relacionados

Scroll al inicio