JC091 Débitmètre électromagnétique compact à insertion

JC091 insertion electromagnetic flowmeter is a new fluid flowmeter developed based on a pipe-type electromagnetic flowmeter. It is suitable for large pipe sizes with low cost.

  • Durée du prix: FOB/CIF/EXW/DAP
  • Paquet: Caisse en bois exportée ou selon la demande du client
  • Délai de livraison7 à 10 jours ouvrables
  • Transports: Par mer, par air, par grand express
  • Port d'embarquement: Port de Shanghai
  • Origine du lieu: Jiangsu
  • Garantie: 12 mois

JC091 insertion electromagnetic flowmeter is a new fluid flowmeter developed based on a pipe-type electromagnetic flowmeter. Besides preserving the merits of the pipe-type electromagnetic flowmeter and considering such defects of pipe-type electromagnetic flowmeter as difficult installation on large pipes and high cost, JC091 flowmeter measures mean fluid flow rate in the electromagnetic method according to NIKURADS principle, so as to obtain the fluid volume flow. In particular, after technologies of hot tapping and installation under pressure are applied, the insertion electromagnetic flowmeter can be installed without conducting shutdown or cutting off the water supply as well as on cast iron pipe or cement pipe. The successful development of the insertion electromagnetic flowmeter provides a new means for inspection of fluid flow.

Compared to an ordinary electromagnetic flowmeter, the sensor of insertion electromagnetic flowmeter generates an external emission magnetic field on the outer side. The measuring electrodes are at the ends or on both sides of the sensor. The principle of the electromagnetic flowmeter is shown in the figure below. It is noteworthy that in the external emission magnetic field, the induction signal of the electromagnetic flow sensor will reduce the linearity of measurement in case of being affected by fluid and thickness of the magnetic field’s boundary layer.

In terms of the JC091 insertion electromagnetic flowmeter, conducting liquid in the pipeline is the conductor moving in the magnetic field, and the distance between two electrodes is the length (L) of the conductor.

 

 

JC091

Power:24 VDC or 220 VAC

  

 

Débitmètre électromagnétique inséré Débitmètre électromagnétique à distance
Compact  type Remote control  type
 

JC091

Power: Battery type

Insertion-débitmètre électromagnétique Débitmètre électromagnétique à pile
With a built-in  pressure sensor IP 68
Précision ±0.5%~±1.5% (under reference conditions)
Caliber (mm) DN100~DN3000 DN100~DN3000
Bride Conforming to GB9119, stainless steel
Pressure rating 1,6MPa
Material of converter housing Die-cast aluminum alloy
Material of sensor housing Acier inoxydable
Material of sensor structure Stainless steel/PVDF
Poids 6 kg
Electrical conductivity ≥5μs/cm (negotiate with us for ordering in case of less than 5μs/cm)
Electrode  316L, Hastelloy, titanium, tantalum, and platinum
Protection grade IP65 IP65/IP67(IP68 is optional to the sensor)
Medium temperature -25℃~80℃ -25℃~120℃
Température ambiante -25℃~60℃
Effect of ambient temperature <±0.1%/10℃ or <±0.25%/10℃
Repetitiveness ≤±0.01% or ≤±0.25%
Analog output error ≤±0.02mA
Flow rate within measuring range ≤10m/s
Available to be buried — ≤5m (only IP68)
Electrical connection M20*1.5 seals, G1/2 and NPT1/2
Sensor cable <30M (negotiate with us for ordering in case of over length)
Code Diamètre nominal

(mm)

Plage de débit

(m3/h)

Code Diamètre nominal (mm) Plage de débit

(m3/h)

JC091-100

JC091-125

JC091-150

JC091-200

JC091-250

JC091-300

JC091-350

JC091-400

JC091-450

JC091-500

JC091-600

JC091-700

JC091-800

JC091-900

JC091-1000

DN100

DN125

DN150

DN200

DN250

DN300

DN350

DN400

DN-450

DN-500

DN-600

DN-700

DN-800

DN-900

DN-1000

8.48~282.6

13.25~441.56

19.08~635.85

33.91~1130.40

52.99~1766.25

76.30~2543.40

103.86~3461.85

135.65~4521.60

171.00~5722.65

211.95~7065.00

305.21~10173.00

415.42~13847.40

542.59~18086.40

686.72~22890.60

847.80~28260.00

JC091-1200

JC091-1400

JC091-1600

JC091-1800

JC091-2000

JC091-2200

JC091-2400

JC091-2600

DN-1200

DN-1400

DN-1600

DN-1800

DN-2000

DN-2200

DN-2400

DN-2600

1220.83~40694.40

1661.69~55389.60

2170.37~72345.60

2746.87 ~91562.40

3391.20~113040.00

4103.35~136778.40

4883.33~162777.60

5731.13~191037.60

Code Matériau de l'électrode
K1

K2

K3

K4

K5

K6

K7

SS 316L

Hastelloy B

Hastelloy C

Titane

Tantale

Alliage Pt/Iridium

Peinture sur acier inoxydable Carbure de tungstène

Code Matériau du revêtement
C1 PVDF
Code Fonction
E1

E2

E3

F1

F2

F3

F4

T1

T2

T3

P1

P2

P3

P4

P0

D1

D2

D3

J1

J2

J3

J4

Class 1.5%

Classe 1.0%

Class 2.5%

4~20mADC, charge ≤750Ω

0~3kHz, 5V actif, impulsion modifiable, borne haute et sortie fréquence effective

Interface RS 485 (Modbus)

HART

Température normale

Haute température

Ultra Température

1,0MPa

1,6MPa

4,0MPa

16MPa

Pression spéciale

220VAC+10%; 50Hz+ 1Hz

24VDC+10%

Fonctionnement sur piles

Type intégral

Type à distance

Antidéflagrant

With built-in pressure sensor

JC091 Compact Insertion Electromagnetic Flowmeter-1

Installation-JC091 Compact Insertion Electromagnetic Flowmeter-2

 

Installation-JC091 Compact Insertion Electromagnetic Flowmeter

Produits apparentés

Retour en haut