JCMF Débitmètre massique à Coriolis de type déporté
JCMF Coriolis mass flowmeter provides the best mass flow, density, and temperature measurement performance, and also calculates volume flow, total flow, and fluid composition in real-time.
- Durée du prix: FOB/CIF/EXW/DAP
- Paquet: Caisse en bois exportée ou selon la demande du client
- Délai de livraison7 à 10 jours ouvrables
- Transports: Par mer, par air, par grand express
- Port d'embarquement: Port de Shanghai
- Origine du lieu: Jiangsu
- Garantie: 12 mois
- Introduction
- Paramètres
- Fonctionnalité
- Modèle
- Dimension
- Installation
JCMF Débitmètre massique à Coriolis de type déporté
JCMF Coriolis mass flowmeter provides the best mass flow, density, and temperature measurement performance, and also calculates volume flow, total flow, and fluid composition in real-time. Currently, it has three styles available which are M type sensor, U type sensor, and S type sensor. Meanwhile, each series has its own compact and remote meters.
In general, a typical mass flowmeter is made up of a flow sensor and a signal transmitter. The flow sensor is designed to equip two flow tubes for vibration which resulting in signals for pickoff; The signal transmitter is employed with the digital signal processor (DSP), and dynamic vibration balance (DVB) circuit to deliver fast response but accurate measurement performance. In addition, in situ node-configuration, diagnostics, and data recording are easily handled via HART or Modbus RTU communication.
Matériau
Tubes: SS316L ( Hastelloy C for options)
Flow Splitter: SS304 (SS316L and Hastalloy C for options)
Flanges: SS304 ( (SS316L and Hastalloy C for options)
Housing case (NON-WETTED PARTS) SS304(SS316L for options )
Options: NACE MR 0175/0103 compliant
| Titles | Technical Specifications |
| Applicable medium | Pure liquid, liquid with multiform, high viscosity, high-density gas |
| Items of measurement | Flow rate, Gross, Temperature, Density(different percentage, alcohol content |
| Affichage | LCD(or LED) English(Chinese) |
| Mass flow accuracy | ±[0.2% +(zero stability /flow rate×100%)] |
| Mass flow repeatability | ±(1/2) ×[0.2% +(zero stability /flow rate×100%)] |
| Gamme de densité | 0.2 g/cm3~3.5g/cm3 |
| Density accuracy | ±0.002g/cm3 |
| Plage de température | -60℃~+200℃(-60℃~+300℃, -200℃~+100℃) |
| Temperature accuracy | ±1℃ |
| Pressure rating | 30MPa, 4MPa, 2.5MPa |
| Output of signal | 4mA~20mA, 0Hz~10kHz |
| Communication | RS485/MODBUS, or HART |
| Form of transmitter | Cabinet mount(split type), field mount(integrate) |
| Matériau | 316L(tube), 304(others) |
| Code of exploration proof | ExibIICT6Gb, ExibIIBT4Gb |
| Niveau de protection | IP67 |
| Contactor capacity of a Batch Control relay | 24V/0.1A |
| Contactor form | normal open |
| Environmental temperature range | 0℃~+40℃,(-40℃~+40℃) |
| Environmental humidity | ≤90% RH, non condensation |
| Atmospheric pressure range | 86kPa~106kPa |
| Power supply of transmitters | DC (24±10%) V, AC(220±10%)V |
| Power consumed | <15W |
CARACTÉRISTIQUES
- Robust, no moving parts for long life
- Custom flow connectors& installation lengths Excellent repeatability (±0.05%of flow rate) Optional Net Oil functionality
- NIST Traceable NTEP certificates for custody transfer
- Increased productivity, less maintenance Lower installation cost
- Increased product quality
- Simpler whole solution for Net Oil without PLC/RTU
| Type | Line Sizes | Flow Range(t/h) | Type | Line Sizes | Flow Range(t/h) |
| JCMF-DN1 | DN1 | 0~0.02 | JCMF-DN 32 | DN32 | 0~20 |
| JCMF-DN2 | DN2 | 0~0.06 | JCMF-DN 40 | DN40 | 0~40 |
| JCMF-DN3 | DN3 | 0~0.35 | JCMF-DN 50 | DN50 | 0~65 |
| JCMF-DN6 | DN6 | 0~0.7 | JCMF-DN 65 | DN65 | 0~80 |
| JCMF-DN10 | DN10 | 0~1.2 | JCMF-DN 80 | DN80 | 0~160 |
| JCMF-DN15 | DN15 | 0~6.4 | JCMF-DN 100 | DN100 | 0~250 |
| JCMF-DN20 | DN20 | 0~8.0 | JCMF-DN 125 | DN125 | 0~280 |
| JCMF-DN25 | DN25 | 0~16 | JCMF-DN 150 | DN150 | 0~550 |
| H | Form of Structure | ||||||||
| H1 | Compact type | ||||||||
| H2 | Remote control with cable | ||||||||
| P | Tube Pressure Range | ||||||||
| P1 | 2.5MPa(DN80~DN150) | ||||||||
| P2 | 4.0MPa(DN15~DN65) | ||||||||
| P3 | 4.0MPa, or 30MPa(DN1~DN10) | ||||||||
| P4 | Special Order | ||||||||
| T | Plage de température | ||||||||
| T1 | (-60~200℃) | ||||||||
| T2 | (-60~300℃)High Temp.,(-200~100℃)Low Temp. | ||||||||
| O | Sortie | ||||||||
| O1 | 4~20mA,0~10KHz(Pulse) | ||||||||
| O2 | Null | ||||||||
| C | Communication | ||||||||
| C1 | RS485/Modbus | ||||||||
| C2 | HART | ||||||||
| C3 | Null | ||||||||
| E | Exploration Proof | ||||||||
| E1 | Remote ExibIIBT4Gb | ||||||||
| E2 | Compact type ExdibIICT6Gb | ||||||||
| A | Precision | ||||||||
| A1 | 0.1~0.15% | ||||||||
| A2 | 0.2% | ||||||||
| B | Batch Control | ||||||||
| B1 | Null | ||||||||
| B2 | Batch Control | ||||||||
| P | Alimentation électrique | ||||||||
| P1 | 24VDC | ||||||||
| P2 | 220VAC | ||||||||
Dimension for JCMF Remote type Coriolis Mass Flowmeter

Dimensions Table 1
| Spec | Line sizes(mm) | Fitting Options (mm) | Number and Hole Diameter of Flange join or Screw join (mm) | Poids
(kg) |
|||
| A | B | C | D | ||||
| DN1 | 1 | 214 | 212 | 70 | (237) | M16×1.5 Screw join | 6 |
| DN2 | 2 | 214 | 221 | 70 | (277) | M16×1.5 Screw join | 6.5 |
| DN3 | 3 | 214 | 234 | 70 | (329) | M16×1.5 Screw join | 7.5 |
| DN6 | 6 | 214 | 234 | 70 | (329) | M16×1.5 Screw join | 7.5 |
| DN10 | 10 | 260 | 288 | 73 | (364) | M20×1.5 Screw join | 9 |
| DN15 | 15 | 379 | 479 | 90 | φ65 | 4-φ14 | 15 |
| DN25 | 25 | 472 | 539 | 96 | φ85 | 4-φ14 | 18.5 |
| DN40 | 40 | 522 | 623 | 116 | φ110 | 4-φ18 | 25.5 |
| DN50 | 50 | 597 | 685 | 137 | φ125 | 4-φ18 | 35 |
| DN80 | 80 | 650 | 835 | 175 | φ160 | 8-φ18 | 53.5 |
| DN100 | 100 | 714 | 938 | 198 | φ190 | 8-φ22 | 70 |
| DN150 | 150 | 815 | 1129 | 265 | φ250 | 8-φ26 | 85 |







Débitmètre massique à Coriolis JCMF