JC010 Débitmètre massique thermique de gaz

JC010 Thermal Mass Gas Flow Meter can measure the mass and volume flow rate of gas without humidity and pressure compensation.

  • Durée du prix: FOB/CIF/EXW/DAP
  • Paquet: Caisse en bois exportée ou selon la demande du client
  • Délai de livraison7 à 10 jours ouvrables
  • Transports: Par mer, par air, par grand express
  • Port d'embarquement: Port de Shanghai
  • Origine du lieu: Jiangsu
  • Garantie: 12 mois

The working principle of JC010 Thermal Mass Gas Flow Meter is that a fluid flowing past a heated temperature sensor removes a known quantity of heat as it passes. In a thermal flowmeter, the fluid has to pass two temperature sensors. One sensor obtains a reference value by measuring the actual process temperature. The second sensor is a heating element and it receives precisely as much energy as is needed to compensate for dispersed heat and maintain a precisely defined temperature difference.

Plus le débit massique est élevé au niveau du capteur de température chauffé, plus la chaleur est dissipée et plus l'élément doit être alimenté en énergie pour maintenir la différence de température.

The heating current, therefore, is a measure of the mass flow of the gas.

Due to the sensor temperature is always 30℃ higher than the medium temperature (environment temperature), and the meter adopts the method of constant differential temperature, therefore the meter does not need to do temperature and pressure compensation in principle.

Introduction-thermal mass flowmeter 1

Dimension - fowmeter de masse thermique

  • Mesure du débit massique, sans compensation de l'humidité et de la pression.
  • Large rangeability, flow velocity: 0.1 Nm/s~100Nm/s.
  • Pas de perte de charge, applicable à toute section de tuyau.
  •  Anti-corrosion, applicable to corrosive gas.
  • Online installation and maintenance.
  • Measures mass flow directly – without additional pressure and temperature inputs
  • Accurate measurement and operation at very low gas pressures and flow rates
  • Negligible pressure drop

Thermal-mass-flow-meter-introduction

Insert type Pipe type
Moyen Single gas ( except acetylene gas) or mixed gas of fixed
Taille du tuyau DN80-6000mm DN15-2000mm
Vélocité 0.1Nm/s~100Nm/s ( standard working condition 20 ℃101.33Kpa)
Précision +1%
Medium temperature -40~200℃
Pression 2.5Mpa 4.0Mpa
Alimentation électrique AC220V or DC24V for integral converter and AC220V for split converter.
Temps de réponse ≦1s
Sortie du signal 4~20mA RS-485,Modbus
Affichage Instantaneous flow, mass flow, volume flow, cumulative flow, Beijing time, running time.
Code IP du capteur IP68
Converter IP code IP67 for integral typeIP 65 for split hanging typeIP 52 for split box type
Explosion proof degrade Exd IΙ CT 4
Code Description Remarque
JC010 Débitmètre massique thermique de gaz
Dn15, Dn20 …. Diameter :DN15 to 6000
F In line integral type Structure
I In line seperated type
PI Insertion type intégral
PL Insertion seperated type
T Threaded ,such as 1/2″NPT Connexion
F Flange , such as 2″,ANSI
W Siège soudé
B Siège soudé + robinet à boisseau sphérique
A0 Sans protection antidéflagrante Antidéflagrant
A1 Avec protection antidéflagrante
T1 -20 à 150 °C Standard Température de travail
T2 -20 à 200 °C Température élevée
P0 Pression négative Pression de service
P1 0-1.0Mpa
P2 0-.1.6 Mpa
P3 0-2,0 Mpa
P4 0-3.0Mpa
D 24 VDC Alimentation électrique
A 220 VAC
O Autres
0 Aucun Sortie du signal
1 4-20ma
2 RS 485
3 4-20ma + Hart
L Avec LCD Affichage
O Sans LCD
B 316SS Matériau du capteur  
L HC
C Ti
O Autres

1.Medium

2.Pipe size

3.Flow rate (min/normal/max)

4.Working temperature

5.Working pressure

6.Process connection

7.Power supply

8.Other special requirement

Application-thermal mass flowmeter

Produits apparentés

Retour en haut