JC0022/JC0522 Pressure Controller
■ The controller uses two forms of sensors, diaphragm-type sensors, and leak-free piston-type sensors.
■ The diaphragm-type sensor can be used for neutral gases such as air and gas and liquid media such as lubricating oil and light fuel oil. Setting a value of the controller
Adjustable, adjustable range -0.1 to 1.6 MPa.
■ Non-leakage piston type sensor can be used for neutral lubricating mediums such as hydraulic oil, lubricating oil, and light fuel oil. The controller setting value can be
Adjustable, with an adjustment range of 0.5 to 40MPa.
■ The controller is a compact design, allowing for a high switching frequency of 100 times/minute and particularly good vibration resistance.
- Price Term: FOB/CIF/EXW/DAP
- Package: Exported Wooden case or according to customer request
- Delivery Time: 7 to 10 working days
- Transports: By sea, by air, by high express
- Shipment Port: Shanghai Port
- Origin of Place: Jiangsu
- Warranty: 12 Months
- Main Technical Performance
- Specification
- External Dimensions And Mounting Dimensions (Unit: mm)
- Electrical Wiring Diagram
Operating Viscosity | <1× 10-3m2/s |
Switching Element | Micro switch |
Enclosure Protection Class | IP54 (According to DIN40050, Equivalent to IP54 in GB4208) |
Installation Position | Pressure connection vertical down (15° tilt allowed) |
Ambient Temperature | -25℃~55℃ |
Medium Temperature | -25℃~80℃ |
Anti-Vibration Performance | Max: 100 m/s2 |
Repeatability Error | ≤2.5% |
Contact Capacity | AC 220V 6A (Resistance) |
JC0022 Switching Difference Is Not Adjustable
Set Value
Adjustment Range Mpa |
Switching
Difference Is Not Greater Than Mpa |
Maximum Allowable Pressure
①Mpa |
Pressure Sensor Materials | Interface type② | Interface Female thread | W
(Kg) |
Dimension
Drawing |
|
Housing | Seals | |||||||
-0.1~0 | 0.02 | 8 | AL | Nitrile rubber | I | G1/4″ | 0.2 | 01 |
-0.1~0 | 0.02 | P | – | 03 | ||||
0.02~0.2 | 0.04 | I | G1/4″ | 01 | ||||
0.02~0.2 | 0.04 | P | – | 03 | ||||
0.05~0.8 | 0.13 | I | G1/4″ | 01 | ||||
0.05~0.8 | 0.13 | P | – | 03 | ||||
0.1~1.6 | 0.24 | I | G1/4″ | 02 | ||||
0.1~1.6 | 0.24 | P | – | 03 |
JC0522 Switching Difference Is Not Adjustable
Set Value
Adjustment Range Mpa |
Switching
Difference Is Not Greater Than Mpa |
Maximum Allowable Pressure
①Mpa |
Pressure Sensor Materials | Interface type② | Interface Female thread | W
(Kg) |
Dimension
Drawing |
||
Housing | Seals | Piston | |||||||
0.5~7 | 2 | 40 | AL | Nitrile rubber | Steel | I | G1/4″ | 0.2 | 04 |
0.5~7 | 2 | P | – | 03 | |||||
1~16 | 3.5 | I | G1/4″ | 04 | |||||
1~16 | 3.5 | P | – | 03 | |||||
2.5~25 | 4 | I | G1/4″ | 05 | |||||
2.5~25 | 4 | P | – | 03 | |||||
4~40 | 4.5 | I | G1/4″ | 05 | |||||
4~40 | 4.5 | P | – | 03 |
Note: ①In practice, even brief pressure peaks must not exceed this value.
②I-Interface is female thread P-Interface is flange
Controller Selection And Installation Instructions
See controller selection and installation for details
Adjustment Of The Set Value
For details, see the adjustment of the pressure controller set value example 4
505-18D O-ring dimensions:Φ 5× 15
The process of single knife double-throw micro switch action.
Wiring terminal 1-2 pressure rise to the upper switching value is disconnect;
Wiring terminal 1-3 pressure rise to the upper switching value is switched on.