JC0515 Pressure Controller

 The controller adopts the sensor of the non-leakage piston type, which can be used for neutral gases such as compressed air containing oil mist and hydraulic oil, water-oil emulsion liquid and have good lubrication performance of the liquid medium that does not have a corrosive effect on the pressure sensor material.

 The setting value of the controller is adjustable. The range of adjustment is 0.5 to 25MPa.

 Compact structure, small size, and good anti-vibration performance.

  • Price Term: FOB/CIF/EXW/DAP
  • Package: Exported Wooden case or according to customer request
  • Delivery Time:  7 to 10 working days
  • Transports: By sea, by air, by high express
  • Shipment Port: Shanghai Port
  • Origin of Place: Jiangsu
  • Warranty: 12 Months
Operating Viscosity <1× 10-3m2/s
Switching Element Micro switch
Enclosure Protection Class IP54 (According to DIN40050, Equivalent to IP54 in GB4208)
Medium Temperature 0~90℃
Ambient Temperature -5℃~50℃(Grooved seal)

-30℃~50℃(GLYdring seal)

Anti-Vibration Performance Max:100 m/s2
Installation Position Pressure connection vertical down (15° tilt allowed)
Repeatability Error ≤2.5%
Contact Capacity AC  220V  6A (Resistance)

Switching Difference Is Not Adjustable

Set Value

Adjustment

Range  Mpa

Switching

Difference Is Not Greater Than  Mpa

Maximum Allowable Pressure

Mpa

Switching Times

Times/Min

Pressure Sensor Materials Pressure

Interface type②

Interface Female thread W

Kg

Dimension

Drawing

Housing Seals  Piston
Adjust The Setting With The Hexagonal Screw With Plastic Protective Cover:
0.5~7 1.2 25 20 AL Nitrile rubber Stainless Steel

1Cr18

Ni9Ti

I G1/4″ 0.4 01
0.5~7 1.2 25 P 02
1~16 1.8 25 I G1/4″ 01
1~16 1.8 25 P 02
5~25 1.6 34 I G1/4″ 01
5~25 1.6 34 P 02

 

Note: ①In practice, even brief pressure peaks must not exceed this value.

②I-Interface is female thread    P-Interface is flange

③for GLydring seal specifications

 

Controller Selection And Installation Instructions

See controller selection and installation for details

Adjustment Of The Set Value

For details, see the adjustment of the pressure controller set value example 4

01

Pressure Controller

02

Pressure Controller

Electrical Wiring Diagram

The process of single knife double-throw micro switch action.

Wiring terminal 1-3 pressure rise to the upper switching value is disconnect;

Wiring terminal 1-2 pressure rise to the upper switching value is switched on.

Get Our Best Quotation