JC1102 Explosion-proof pressure Controller

The pressure controller and Explosion-proof pressure Controller uses bellows type sensors for corrosive gases and liquid media

  • Price Term: FOB/CIF/EXW/DAP
  • Package: Exported Wooden case or according to customer request
  • Delivery Time:  7 to 10 working days
  • Transports: By sea, by air, by high express
  • Shipment Port: Shanghai Port
  • Origin of Place: Jiangsu
  • Warranty: 12 Months

 The setting value of the pressure controller is adjustable, and the adjustment,Range -0.1~6.3MPa

 Large temperature range, can be used for corrosive media

Normal  Type Explosion-proof
Operating Viscosity <1× 10-3m2/s <1× 10-3m2/s
Switching Element Micro switch Sealed Switches
Explosion Protection Class Exde Ⅱ CT4~T6 Certificate of Conformity No.: GYB19.1360X
Enclosure Protection Level IP65(Conforms to DIN40050, equivalent to  IP65 in GB4208) IP54 (Conforms to DIN40050, equivalent to  IP54 in  GB4208)
Ambient Temperature -40℃~50℃ -20℃~50℃
Medium Temperature 0~120℃ 0~95℃
Installation Position Pressure connection vertically down
Anti-Vibration Performance TL0202:40m/s2 ;TL0203:20m/s Max: 20m/s2
Repeatability Error ≤1% ≤1%
Contact Capacity AC  220V  6A (Resistance) DC 250V  0.25A(Resistance)  60Wmax

AC 250V  5A(Resistance)  1250VAmax

JC1102 Switching Difference Is Not Adjustable 

Set Value

Adjustment

Range  Mpa

Switching

Difference Is Not Greater Than  Mpa

Maximum Allowable Pressure

Mpa

Switching

Times

Times/Min

 

 Pressure Sensor Materials Interface Male Thread W

Kg

 Dimension Drawing
Housing Bellows Normal Ex-Proof
-0.1~0 0.007 1 20 1Cr18Ni9

Ti

00Cr17Ni

14Mo2

(316L)

G1/2″ 1.0 01 04
-0.1~0.1 0.008
-0.1~0.16 0.009
-0.1~0.25 0.012
0~0.1 0.008
0~0.16 0.009
0.01~0.25 0.01
0.02~0.4 0.03 2 0.85 02 05
0.03~0.6 0.035
0.03~1 0.04
0.05~1.6 0.08 5 0.9 03 06
0.05~2.5 0.09
0.3~6.3 0.2 8.5

 

JC1102 Switching Difference Is Adjustable

Set Value

Adjustment

Range  Mpa

Switching

Difference Is Not Greater Than  Mpa

Maximum Allowable Pressure

Mpa

Switching

Times

Times/Min

 

 Pressure Sensor Materials Interface Male Thread    W

Kg

 Dimension Drawing
Housing Bellows Normal Ex-Proof
-0.1~0 0.019 1 20 1Cr18Ni9

Ti

00Cr17Ni

14Mo2

(316L)

G1/2″ 1.05 01 04
-0.1~0.1 0.021
-0.1~0.16 0.022
-0.1~0.25 0.024
0~0.1 0.016
0~0.16 0.02
0.01~0.25 0.024
0.02~0.4 0.08 2 0.9 02 05
0.03~0.6 0.09
0.03~1 0.1
0.05~1.6 0.19 5 0.95 03 06
0.05~2.5 0.2
0.3~6.3 0.65 8.5

 

JC1103 Switching Difference Is Not Adjustable (Small Switching Difference, No Explosion-Proof Type)

Set Value

Adjustment

Range  Mpa

Switching

Difference Is Not Greater Than  Mpa

Maximum Allowable Pressure

Mpa

Switching

Times

Times/Min

 

 Pressure Sensor Materials Interface Male Thread    W

Kg

 Dimension Drawing
Housing Bellows
-0.1~0 0.0045 1 20 1Cr18Ni9

Ti

00Cr17Ni

14Mo2

(316L)

G1/2″ 1.0 01
-0.1~0.1 0.005
-0.1~0.16 0.0065
-0.1~0.25 0.01
0~0.1 0.0045
0~0.16 0.006
0.01~0.25 0.007
0.02~0.4 0.016 2 0.85 02
0.03~0.6 0.02
0.03~1 0.03
0.05~1.6 0.05 5 0.9 03
0.05~2.5 0.06
0.3~6.3 0.12 8.5

 

Note: ① In actual operation, even brief pressure peaks should not exceed this value.

Instructions For Selection And Installation Of Controller

See selection and installation of controller for details

Adjustment Of The Set Value

For details, see the adjustment of the set value of the pressure controller Example I, Example II, Example V

Normal  Type

01

Pressure switch

02

Pressure switch

03

Pressure switch

Ex-proof  Type

04

Explosion-proof pressure Controller

05

Explosion-proof pressure Controller

06

Explosion-proof pressure Controller

 

Electrical Wiring Diagram

The process of single knife double-throw micro switch action.

Wiring terminal 1-3 pressure rise to the upper switching value is switched on;

Wiring terminal 1-2 pressure rise to the upper switching value disconnect.

Scroll to Top