JC3007/JC3008 Differential Pressure Switch

The BCST differential pressure switch consists of 2 diaphragm cavities, and the two cavities are sealed by two sealing diaphragms and a differential pressure sensing diaphragm. The high pressure and low pressure enter the high pressure chamber and low pressure chamber of the differential pressure switch respectively, and the sensed differential pressure deforms the pressure-sensing diaphragm, which eventually activates the micro switch at the top end through mechanical structures such as the bar spring to make the electrical signal output.

  • Price Term: FOB/CIF/EXW/DAP
  • Package: Exported Wooden case or according to customer request
  • Delivery Time:  7 to 10 working days
  • Transports: By sea, by air, by high express
  • Shipment Port: Shanghai Port
  • Origin of Place: Jiangsu
  • Warranty: 12 Months

The JC3007 differential pressure switch uses a bellows type sensor and can be used for corrosive gases and liquid medium.

The JC3007 differential pressure switch has an adjustable set value and an adjustment range of 0.02 to 3 MPa and its operating pressure range is 0.05 to 6.3 MPa.

Normal Type Ex-proof Type
Operating Viscosity <1× 10-3m2/s <1× 10-3m2/s
Switching Elements

 

Microswitch Sealed Switches
Ex-proof Rating

 

Exde Ⅱ CT4~T6 Code: GYB19.1360X
Enclosure Protection Class

 

IP65 (in accordance with DIN40050, equivalent to IP65 in GB4208) IP54 (in accordance with DIN40050, equivalent to IP54 in GB4208)
Ambient Temperature

 

-5℃~40℃ -5℃~50℃
Medium Temperature

 

0~120℃ 0~95℃
Mounting Position

 

Pressure connection vertically downwards
Vibration Resistance

 

TL3007:40m/s2   TL3008:20m/s2 Max:20m/s2
Repeatability Error

 

≤1% ≤1%
Contact Capacity AC  220V  6A(Resistance) DC  250V  0.25A(Resistance)  60Wmax

AC  250V  5A(Resistance)  1250VAmax

JC 3007 switching differential non-adjustable

Differential Pressure Setting Constant Value Adjustment Range(MPa) Switching differential not greater than(MPa) Working  Pressure Range

(MPa)

Max. Pressure

(MPa)

Switching range Switching times

(T/M)

Pressure Sensor Material Interface male thread Weight

(kg)

Dimensional drawing
Housing Bellows Normal Ex-proof
0.02-0.1 0.04 0.05-1.6 2 10 Stainless steel 1Cr18 Ni9 Ti Stainless steel 00Cr17N i 14Mo2 (316L) G1/2’’ 1.10 01 03
0.02-0.16 0.04
0.025-0.25 0.05
0.03-0.4 0.06
0.05-0.6 0.1 0.1-2.5 3 1.05 02 04
0.05-1 0.12
0.05-1.6 0.14
0.1-3 0.2 0.4-6.3 7

JC3008 Switching differential not adjustable for smaller switching differentials, non-explosion-proof type

Differential Pressure Setting Constant Value Adjustment Range(MPa) Switching differential not greater than(MPa) Working  Pressure Range

(MPa)

Max. Pressure

(MPa)

Switching range Switching times

(T/M)

Pressure Sensor Material Interface male thread Weight

(kg)

Dimensional drawing
Housing Bellows Normal
0.02-0.1 0.02 0.05-1.6 2 10 Stainless steel 1Cr18 Ni9 Ti Stainless steel 00Cr17N i 14Mo2 (316L) G1/2’’ 1.10 01
0.02-0.16 0.02
0.025-0.25 0.025
0.03-0.4 0.03
0.05-0.6 0.05 0.1-2.5 3 1.05 02
0.05-1 0.06
0.05-1.6 0.06
0.1-3 0.15 0.4-6.3 7

Note:  ①The pressure range of the medium at the high pressure port.

②In practice, the brief pressure peaks of the medium at both pressure ports must not exceed this value either.

 

Normal Type

01

Differential Pressure Switch

 

02

Differential Pressure Switch

 

Ex-proof Type

03

Ex-proof Differential Pressure Switch

 

04

Ex-proof Differential Pressure Switch

 

Electrical Wiring Diagram

Scroll to Top