JC4212 Temperature Controller
■ The controller adopts inline temperature package sensor, which can be used for flowing neutral gas and liquid media, and the temperature package protection tube is stainless steel. Can be used for corrosive media. The setting value of the controller is adjustable, and the adjustment range is from 0 to 280℃
- Price Term: FOB/CIF/EXW/DAP
- Package: Exported Wooden case or according to customer request
- Delivery Time: 7 to 10 working days
- Transports: By sea, by air, by high express
- Shipment Port: Shanghai Port
- Origin of Place: Jiangsu
- Warranty: 12 Months
- Main Technical Performance
- Specification
- External Dimensions And Mounting Dimensions (unit: mm)
- Electrical Wiring Diagram
Ordinary type | Explosion-proof type | |
Switching Components | Micro switch | Sealed Switches |
Explosion-Proof Grade | — | Exde Ⅱ CT4~T6 Certificate of Conformity No.: GYB19.1360X |
Enclosure Protection Level | IP65 (in accordance with DIN40050, equivalent to IP65 in GB4208) | IP54 (according to DIN40050, equivalent to IP54 in GB4208) |
Ambient Temperature | -25℃~50℃
|
-25℃~50℃
|
Switch Components Mounting
Location |
— | Perpendicular to the horizontal plane |
Vibration Resistance | Max:40m/s2
|
Max:20m/s2
|
Warm Package Material | Stainless Steel | Stainless Steel |
Repeatability Error | ≤3%
|
≤3%
|
Contact Capacity | AC 220V 6A (Resistance) | DC 250V 0.25A(Resistive) 60Wmax
AC 250V 5A(Resistive) 1250VAmax |
JC4212 Switching Difference Is Not Adjustable
Set Value Adjustment Range
Range ℃
|
Switching Difference Is Not
Greater Than ℃ |
Maximum Allowable
Temperature ℃ |
Thread | Temperature Package Protection
Tube D(Mm)
|
Insertion Depth
L(Mm) |
Dimensional Drawing | |
Ordinary Type | Explosion-Proof Type | ||||||
+10~+75
|
2.5
|
95 | M20×1.5
|
φ14
|
120 | 01 | 02 |
+60~+165
|
4 | 190 | |||||
+160~+280
|
6 | 320 | |||||
0~+40
|
5 | 80 | 150 |
JC4212 Switching Difference Is Adjustable
Set Value Adjustment Range
Range ℃
|
Switching Difference Is Not
Greater Than ℃ |
Maximum Allowable
Temperature ℃ |
Thread | Temperature Package Protection
Tube D(Mm)
|
Insertion Depth
L(Mm) |
Dimensional Drawing | |
Ordinary Type | Explosion-Proof Type | ||||||
+10~+75
|
2.5
|
95 | M20×1.5
|
φ14
|
120 | 01 | 02 |
+60~+165
|
4 | 190 | |||||
+160~+280
|
6 | 320 | |||||
0~+40
|
5 | 80 | 150 |
Note: The diameter D and insertion depth L of the temperature package protection tube should be specified in the order, and the thread should be specified in the order if there are special requirements.
Single knife double-throw micro switch action process.
Wiring 1-3 temperature rise to the switching value is switched on;
Wiring terminal 1-2 temperature rise to the upper switching value is disconnected.