JC0102/ JC0103 Pressure Controller

Our controller adopts diaphragm type sensor, some specifications of the sensor shell material is stainless steel, can be used for corrosive media, also can be used for air, gas, water vapor and other neutral gases and oil and other liquid media.

  • Price Term: FOB/CIF/EXW/DAP
  • Package: Exported Wooden case or according to customer request
  • Delivery Time:  7 to 10 working days
  • Transports: By sea, by air, by high express
  • Shipment Port: Shanghai Port
  • Origin of Place: Jiangsu
  • Warranty: 12 Months

 The setting value of the controller is adjustable,The adjustment range is 0~1MPa.

 High control sensitivity in the low pressure range.

Normal  Type Explosion-proof
Operating Viscosity

 

<1×10-3m2/s <1×10-3m2/s
Switching Element Micro switch Sealed Switches
 

Explosion Protection Class

Exde Ⅱ CT4~T6 Certificate of Conformity No.: GYB19.1360X
 

Enclosure Protection Level

 

IP65(Conforms to DIN40050, equivalent to  IP65 in GB4208) IP65 (Conforms to DIN40050, equivalent to  IP65 in  GB4208)
Ambient Temperature -5℃~40℃ -5℃~40℃
Medium Temperature 0~120℃ 0~95℃
Installation Position Pressure connection vertically down
Anti-Vibration Performance 20m/s2 Max: 20m/s2
Repeatability Error ≤1.5% ≤1.5%
 

Contact Capacity

AC  220V  6A (Resistance) DC 250V  0.25A(Resistance)  60Wmax

AC 250V  5A(Resistance)  1250VAmax

JC0102 Switching Difference Is Not Adjustable 

Set Value

Adjustment

Range  Mpa

Switching

Difference Is Not Greater Than  Mpa

Maximum Allowable Pressure

Mpa

Switching Times

Times/Min

Pressure Sensor Materials Interface Female Thread     W

Kg

 Dimension Drawing
Housing Diaphragm Normal Ex-Proof
0~0.01 0.0012  

0.1

10 Stainless Steel Stainless Steel

00Cr17

Ni14

Mo2

(316L)

 

G1/4″

 

0.9

01 03
0~0.025 0.0018
0~0.04 0.0025
0.05~0.4 0.06 10② Stainless Steel

1Cr18Ni

9Ti

02 04
0.05~0.6 0.07
0.05~1 0.1

 

JC0102 Switching Difference Is Adjustable

Set Value

Adjustment

Range  Mpa

Switching

Difference Is Not Greater Than   Mpa

Maximum Allowable Pressure

Mpa

Switching Times

Times/Min

Pressure Sensor Materials Interface Female Thread     W

Kg

Dimension Drawing
Housing Diaphragm Normal Ex-Proof
0~0.01 0.004  

0.1

10 Stainless Steel Stainless Steel

00Cr17

Ni14

Mo2

(316L)

G1/4″ 0.95 01 03
0~0.025 0.005 0.9
0~0.04 0.007 0.95
0.05~0.4 0.18 10② Stainless Steel

1Cr18Ni

9Ti

0.95 02 04
0.05~0.6 0.22
0.05~1 0.3

 

JC0103 Switching Difference Is Not Adjustable (Small Switching Difference, No Explosion-Proof Type)

Set Value

Adjustment

Range  Mpa

Switching

Difference Is Not Greater Than   Mpa

Maximum Allowable Pressure

Mpa

Switching

 Times

Times/Min

 

 Pressure Sensor Materials Interface Female Thread     W

Kg

Dimension Drawing
Housing Diaphragm Normal Ex-Proof
0~0.01 0.0006 0.1 10 Stainless Steel Stainless Steel

00Cr17

Ni14

Mo2

(316L)

G1/4″ 0.9 01
0~0.025 0.001
0~0.04 0.0018
0.05~0.4 0.035 10② Stainless Steel

1Cr18Ni

9Ti

02
0.05~0.6 0.04
0.05~1 0.05

Note: ①In practice, even brief pressure peaks must not exceed this value.

② refers to the static pressure value.

 

Adjustment Of The Set Value

See the adjustment of the set value of the pressure controller in Example 1, Example 2 and Example 5

Selection And Installation

See Selection and installation of the controller for details

Normal  Type

01

Pressure switch

02

Pressure switch

Ex-proof  Type

03

Explosion-proof pressure Controller

 

04

 

Explosion-proof pressure Controller

Electrical Wiring Diagram

Single knife double-throw micro switch action process:

Wiring terminal 1-2 pressure rise to the switching value is disconnected;

Wiring terminal 1-3 pressure rise to the upper switching value on.

Get Our Best Quotation