JC091 Insertion Remote Electromagnetic Flowmeter
JC091 Insertion Battery Electromagnetic Flowmeter is a new fluid flowmeter developed based on pipe-type electromagnetic flowmeter. Besides preserving the merits of pipe-type electromagnetic flowmeter and considering such defects of pipe-type electromagnetic flowmeter as difficult installation on large pipes and high cost.
- Introduction
- Parameters
- Model
- How to Order
- Video
JC091 Insertion Remote Electromagnetic FlowmeterÂ
JC091 Insertion Remote Electromagnetic Flowmeter is a new fluid flowmeter developed based on pipe-type electromagnetic flowmeter. Besides preserving the merits of pipe-type electromagnetic flowmeter and considering such defects of pipe-type electromagnetic flowmeter as difficult installation on large pipes and high cost.
Compared to ordinary electromagnetic flowmeter, sensor of insertion electromagnetic flowmeter generates external emission magnetic field on outer side. The measuring electrodes are at the ends or on both sides of the sensor. Principle of electromagnetic flowmeter is shown in the figure below. It is noteworthy that in external emission magnetic field, the induction signal of electromagnetic flow sensor will reduce the linearity of measurement in case of being affected by fluid and thickness of the magnetic field’s boundary layer.
In terms of JC091 insertion electromagnetic flowmeter, conducting liquid in pipeline is the conductor moving in magnetic field and distance between two electrodes is the length (L) of conductor.
Technical Parameter for JC091 Insertion Remote Electromagnetic FlowmeterÂ
Â
JC091 Power :24 VDC or 220 VAC    |
![]() |
![]() |
Compact  type | Remote control  type | |
Â
JC091 Power :Battery type |
![]() |
![]() |
With built in  pressure sensor | IP 68 | |
Accuracy | ±0.5%~±1.5% (under reference conditions) | |
Caliber (mm) | DN100~DN3000 | DN100~DN3000 |
Flange | Conforming to GB9119, stainless steel | |
Pressure rating | 1.6MPa | |
Material of converter housing | Die-cast aluminum alloy | |
Material of sensor housing | Stainless steel | |
Material of sensor structure | Stainless steel/PVDF | |
Weight | 6 kg | |
Electrical conductivity | ≥5μs/cm (negotiate with us for ordering in case of less than 5μs/cm) | |
Electrode | 316L, hastelloy, titanium, tantalum and platinum | |
Protection grade | IP65 | IP65/IP67(IP68 is optional to sensor) |
Medium temperature | -25℃~80℃ | -25℃~120℃ |
Ambient temperature | -25℃~60℃ | |
Effect of ambient temperature | <±0.1%/10℃ or <±0.25%/10℃ | |
Repetitiveness | ≤±0.01% or ≤±0.25% | |
Analog output error | ≤±0.02mA | |
Flow rate within measuring range | ≤10m/s | |
Available to be buried | — | ≤5m (only IP68) |
Electrical connection | M20*1.5 seal, G1/2 and NPT1/2 | |
Sensor cable | <30M (negotiate with us for ordering in case of over length) |
Model Selection for JC091 Insertion Remote Electromagnetic Flowmeter
Code | Nominal Diameter
(mm) |
Flow Range
(m3/h) |
Code | Nominal Diameter (mm) | Flow Range
(m3/h) |
|||||||
JC091-100
JC091-125 JC091-150 JC091-200 JC091-250 JC091-300 JC091-350 JC091-400 JC091-450 JC091-500 JC091-600 JC091-700 JC091-800 JC091-900 JC091-1000 |
DN100
DN125 DN150 DN200 DN250 DN300 DN350 DN400 DN-450 DN-500 DN-600 DN-700 DN-800 DN-900 DN-1000 |
8.48~282.6
13.25~441.56 19.08~635.85 33.91~1130.40 52.99~1766.25 76.30~2543.40 103.86~3461.85 135.65~4521.60 171.00~5722.65 211.95~7065.00 305.21~10173.00 415.42~13847.40 542.59~18086.40 686.72~22890.60 847.80~28260.00 |
JC091-1200
JC091-1400 JC091-1600 JC091-1800 JC091-2000 JC091-2200 JC091-2400 JC091-2600 |
DN-1200
DN-1400 DN-1600 DN-1800 DN-2000 DN-2200 DN-2400 DN-2600 |
1220.83~40694.40
1661.69~55389.60 2170.37~72345.60 2746.87 ~91562.40 3391.20~113040.00 4103.35~136778.40 4883.33~162777.60 5731.13~191037.60 |
|||||||
Code | Electrode Material | |||||||||||
K1
K2 K3 K4 K5 K6 K7 |
SS 316L
Hastelloy B Hastelloy C Titanium Tantalum Pt/Iridium Alloy Stainless Steel Painting Tungsten Carbide |
|||||||||||
Code | Material of liner | |||||||||||
C1 | PVDF
|
|||||||||||
Code | Function | |||||||||||
E1
E2 E3 F1 F2
F3 F4 T1 T2 T3 P1 P2 P3 P4 P0 D1 D2 D3 J1 J2 J3 J4 |
Class 1.5%
Class 1.0% Class 2.5% 4~20mADC, load ≤750Ω 0~3kHz, 5V active, changeable pulse, high-terminal and effective frequency output RS 485 interface (Modbus) HART Normal Temperature High Temperature Ultra Temperature 1.0MPa 1.6MPa 4.0MPa 16MPa Special Pressure 220VAC+10%; 50Hz+ 1Hz 24VDC+10% Battery Operated Integral Type Remote Type Explosion-proof With built-in pressure sensor |
|||||||||||
How to order JC091 Insertion Remote Electromagnetic Flowmeter
- Medium
- Pipe size
- Working pressure
- Working temperature
- Power supply
- Other requirement
Video -JC091 Insertion Battery Electromagnetic Flowmeter