TLD-20 Explosion-proof Differential Pressure Controller
■ The controller adopts bellows-type sensors and can be used for neutral gases such as air, gas, water vapor and other liquid media such as water, refrigerant and oil, etc.
■ The set value of the controller is adjustable from 0.02 to 1.6MPa and the working pressure from 0.05 to 2.5MPa.
- Price Term: FOB/CIF/EXW/DAP
- Package: Exported Wooden case or according to customer request
- Delivery Time: 7 to 10 working days
- Transports: By sea, by air, by high express
- Shipment Port: Shanghai Port
- Origin of Place: Jiangsu
- Warranty: 12 Months
- Main Technical Performance
- Specification
- External Dimensions And Mounting Dimensions (Unit: mm)
- Electrical Wiring Diagram
Normal Type | Explosion-proof | |
Working Viscosity | <1×10-3m2/s | <1×10-3m2/s |
Switching Element | Micro switch | Sealed Switches |
Explosion Protection Class | — | Exed Ⅱ CT4~T6 Certificate of Conformity No. GYB14.1128X |
Enclosure Protection Level | IP65 (according to DIN40050, equivalent to IP65 in GB4208) | IP54 (according to DIN40050, equivalent to IP54 in GB4208) |
Ambient Temperature | -30℃~50℃ | -20℃~50℃ |
Medium Temperature | 0~120℃ | 0~95℃ |
Installation Position | — | Pressure connection vertical down |
Anti-Vibration Performance | TLD-20: 40m/s2; TLD-20: 20m/s | Max: 20m/s2 |
Repeatability Error | ≤1% | ≤1% |
Contact Capacity | AC 220V 6A (Resistance) | DC 250V 0.25A(Resistance) 60Wmax
AC 250V 5A (resistive) 1250VAmax |
TLD-20 Switching Difference Is Not Adjustable
Differential Pressure Setting Value Adjustment Range MPa | Switching
Difference Is Not Greater Than Mpa |
Working Pressure Range ①
MPa |
Maximum Allowable Pressure②
MPa |
Switching Times
Times/Min
|
Pressure Sensor Materials | Interface Female Thread | W
(Kg) |
Dimension
Drawing |
||
Housing | bellow | Norm | EX | |||||||
0.02~0.1 | 0.015 | 0.05~ 1.6 |
2 | 10 | Brass | Stainless steel 00Cr17Ni14Mo2
(316L) |
G1/4 ″ | 1.20 | 01 | 02 |
0.02~0.16 | 0.017 | |||||||||
0.025~0.25 | 0.02 | |||||||||
0.03~0.4 | 0.025 | |||||||||
0.05~0.6 | 0.07 | 0.1~ 2.5 |
3 | |||||||
0.05~1 | 0.08 | |||||||||
0.05~1.6 | 0.09 |
TLD-20 Switching Difference Is Adjustable
Differential Pressure Setting Value Adjustment Range MPa | Switching
Difference Is Not Greater Than Mpa |
Working Pressure Range ①
MPa |
Maximum Allowable Pressure②
MPa |
Switching Times
Times/Min
|
Pressure Sensor Materials | Interface Female Thread | W
(Kg) |
Dimension
Drawing |
||
Housing | bellow | Norm | EX | |||||||
0.02~0.1 | 0.04 | 0.05~ 1.6 |
2 | 10 | Brass | Stainless steel 00Cr17Ni14Mo2
(316L) |
G1/4 ″ | 1.25 | 01 | 02 |
0.02~0.16 | 0.04 | |||||||||
0.025~0.25 | 0.045 | |||||||||
0.03~0.4 | 0.05 | |||||||||
0.05~0.6 | 0.17 | 0.1~ 2.5 |
3 | |||||||
0.05~1 | 0.18 | |||||||||
0.05~1.6 | 0.2 |
Note: ① Is the range of medium pressure of high pressure port.
② In practice, the short-lived pressure peaks of the medium in the two pressure ports should not exceed this value.
Adjustment Of The Set Value
See the adjustment of the set value of the pressure controller for details in Example 1, Example 2 and Example 3
Selection And Installation
See selection and installation of the controller for details
01
02
Single-pole, double-throw microswitch procedure:
Terminals 1-3 are switched on when the pressure rises to the upper switching value.
Terminals 1-2 are disconnected when the pressure rises to the upper switching value.