TLD-20 Explosion-proof Differential Pressure Controller

 The controller adopts bellows-type sensors and can be used for neutral gases such as air, gas, water vapor and other liquid media such as water, refrigerant and oil, etc.

 The set value of the controller is adjustable from 0.02 to 1.6MPa and the working pressure from 0.05 to 2.5MPa.

  • Price Term: FOB/CIF/EXW/DAP
  • Package: Exported Wooden case or according to customer request
  • Delivery Time:  7 to 10 working days
  • Transports: By sea, by air, by high express
  • Shipment Port: Shanghai Port
  • Origin of Place: Jiangsu
  • Warranty: 12 Months
Normal  Type Explosion-proof
Working Viscosity <1×10-3m2/s <1×10-3m2/s
Switching Element Micro switch Sealed Switches
Explosion Protection Class Exed Ⅱ CT4~T6 Certificate of Conformity No. GYB14.1128X
Enclosure Protection Level IP65 (according to DIN40050, equivalent to IP65 in GB4208) IP54 (according to DIN40050, equivalent to IP54 in GB4208)
Ambient Temperature -30℃~50℃ -20℃~50℃
Medium Temperature 0~120℃ 0~95℃
Installation Position Pressure connection vertical down
Anti-Vibration Performance TLD-20: 40m/s2; TLD-20: 20m/s Max: 20m/s2
Repeatability Error ≤1% ≤1%
Contact Capacity AC  220V  6A (Resistance) DC 250V  0.25A(Resistance)  60Wmax

AC 250V  5A (resistive)   1250VAmax

TLD-20 Switching Difference Is Not Adjustable 

Differential Pressure Setting Value Adjustment Range MPa Switching

Difference Is Not Greater Than  Mpa

Working Pressure Range ①

MPa

Maximum Allowable Pressure②

MPa

Switching Times

Times/Min

 

Pressure Sensor Materials Interface Female Thread W

Kg

Dimension

Drawing

Housing bellow Norm EX
0.02~0.1 0.015 0.05~
1.6
2 10 Brass Stainless steel 00Cr17Ni14Mo2

(316L)

G1/4 ″ 1.20 01 02
0.02~0.16 0.017
0.025~0.25 0.02
0.03~0.4 0.025
0.05~0.6 0.07 0.1~
2.5
3
0.05~1 0.08
0.05~1.6 0.09

 

TLD-20 Switching Difference Is Adjustable

Differential Pressure Setting Value Adjustment Range MPa Switching

Difference Is Not Greater Than  Mpa

Working Pressure Range ①

MPa

Maximum Allowable Pressure②

MPa

Switching Times

Times/Min

 

Pressure Sensor Materials Interface Female Thread W

Kg

Dimension

Drawing

Housing bellow Norm EX
0.02~0.1 0.04 0.05~
1.6
2 10 Brass Stainless steel 00Cr17Ni14Mo2

(316L)

G1/4 ″ 1.25 01 02
0.02~0.16 0.04
0.025~0.25 0.045
0.03~0.4 0.05
0.05~0.6 0.17 0.1~
2.5
3
0.05~1 0.18
0.05~1.6 0.2

 

Note: ① Is the range of medium pressure of high pressure port.

② In practice, the short-lived pressure peaks of the medium in the two pressure ports should not exceed this value.

Adjustment Of The Set Value

See the adjustment of the set value of the pressure controller for details in Example 1, Example 2 and Example 3

Selection And Installation

See selection and installation of the controller for details

01

Differential Pressure Controller

02

Explosion-proof Differential Pressure Controller

 Differential Pressure Controller

Single-pole, double-throw microswitch procedure:

Terminals 1-3 are switched on when the pressure rises to the upper switching value.

Terminals 1-2 are disconnected when the pressure rises to the upper switching value.

Get Our Best Quotation