TLP Series Pressure Controllers
â– Â The TLP series pressure controllers are used to protect compressors in refrigeration or air conditioning units from low suction pressure or high discharge pressure.
â– Â TLP series pressure controllers can also be used to stop compressors and air condenser fans.
â– Â TLP series pressure controllers can also be used for pumps, fire protection, boilers, hydraulics, ironing, vacuum and other equipment.
â– Â The TLP series pressure controllers are available in three types of toggle switches: single knife double throw (SPDT), single knife double throw (DPST), and double knife double throw (DPDT).The pressure switch can be operated according to the required pressure. The TLP series pressure controllers are available with copper gas tank connections for ammonia refrigerant systems, or with stainless steel gas tank connections for corrosive gases such as liquid ammonia or hydraulic systems.
â– Â The TLP series pressure controller’s compact micro switch construction ensures reliable and fast changeover.
â– Â TLP series pressure controllers are CE approved and GIC certified.
- Price Term: FOB/CIF/EXW/DAP
- Package: Exported Wooden case or according to customer request
- Delivery Time: Â 7 to 10 working days
- Transports: By sea, by air, by high express
- Shipment Port: Shanghai Port
- Origin of Place: Jiangsu
- Warranty: 12 Months
- Main Technical Performance
- R410a Technical Parameters
- Electrical Parameters
- Connection Method
- Ordering
- Model And Parameters (unit: MPa)
- Standard Accessories And Dimensions (Unit: Mm)
- Contact Form
- External Dimensions (unit: mm)
Ambient Temperature | -40~+60℃ | Maximum working pressure | Maximum test pressure | ||
Medium Temperature | -40~+120℃ | Low voltage side | 1MPa | Low voltage side | 1.65MPa |
Wire Connection | Inlet hole diameter is 15mm | High voltage side | 3MPa | High voltage side | 3.3MPa |
Ambient Temperature | -40~ 65℃ | Maximum working pressure | Maximum test pressure | ||
Medium Temperature | -40~ 120℃ | Low voltage side | 1.2MPa | Low voltage side | 2.5MPa |
Wire Connection | Inlet hole diameter is 15mm | High voltage side | 4.5MPa | High voltage side | 4.8MPa |
Rated Current (A) | Rated Voltage (V) | A.C.110 | A.C.220 |
Non-induced current | 24 | 16 | |
Induced current | Full load current | 24 | 16 |
Instantaneous current | 144 | 96 |
For special requirements, please add a suffix to the model number:
E – indicates English 7/16-20UNF threaded connection.
MG – indicates capillary connection with 1m length.
A – for stainless steel gas tank components
Custom threaded fittings Example: (RC1/4, NPT1/4M, G1/4, etc.)
M: for male thread          F: for female thread
Form | Model | Low Pressure | High Pressure | Reset Form | Maximum Test Pressure | ||||
Adjustment Range | Differential Pressure | Adjustment Range | Differential Pressure | Low Pressure | High Pressure | Low Pressure | High Pressure | ||
Low Pressure
(L.P.) |
TLP2 | 0-0.2 | 0.04-0.1 | Automatic | 1.7 | ||||
TLP3 | -0.05-0.3 | 0.1-0.2 | Automatic | 1.7 | |||||
TLP6M | -0.05-0.6 | Fixed≦ 0.2 | Manual | 1.7 | |||||
TLP6 | -0.05-0.6 | 0.1-0.4 | Automatic | 1.7 | |||||
TLP10 | 0.1-1.0 | 0.1-0.3 | Automatic | 1.7 | |||||
TLP6W-12S | 0-0.02 | 0.04-0.1 | Automatic | 1.7 | |||||
TLPW-12D | 0.05-0.2 | ≤0.4 | Automatic | 1.7 | |||||
TLP760 Negative Pressure | 0~-0.1 | Automatic | 1.7 | ||||||
High Pressure (H. P) | TLP12D | 0.2-1.2 | 0.1-0.4 | Automatic | 3.3 | ||||
TLP16D | 0.3-1.7 | 0.2-0.5 | Automatic | 3.3 | |||||
TLP20D | 0.4-2.0 | 0.2 0.5 | Automatic | 3.3 | |||||
TLP30D | 0.5-3.0 | 0.5-1.0 | Automatic | 3.3 | |||||
TLP30 | 1.0-3.0 | Fixed≦ 0.4 |
Automatic | 3.3 | |||||
TLP30M | 0.5-3.0 | Fixed≦ 0.4 |
Automatic | 3.3 | |||||
TLP45L | 1.0-4.5 | Fixed≦ 0.4 |
Automatic | 4.8 | |||||
TLP45DL | 1.0-4.5 | 0.5-1.5 | Automatic | 4.8 | |||||
High and low Pressure | TLP830 | -0.05-0.6 | 0.1-0.4 | 0.5-3.0 | Fixed≦ 0.4 |
Automatic | Automatic | 1.7 | 3.3 |
TLP830HM | -0.05-0.6 | 0.1-0.4 | 0.5-3.0 | Fixed≦ 0.4 |
Automatic | Automatic | 1.7 | 3.3 | |
TLP830HLM | -0.05-0.6 | Fixed≦ 0.4 | 0.5-3.0 | Fixed≦ 0.4 |
Manual | Manual | 1.7 | 3.3 | |
TLP1245L | 0.2-1.2 | 0.1-0.5 | 1.0-4.5 | Fixed≦ 0.6 |
Automatic | Automatic | 2.5 | 4.8 | |
TLP1245LHM | 0.2-1.2 | 0.1-0.5 | 1.0-4.5 | Fixed≦ 0.6 |
Automatic | Automatic | 2.5 | 4.8 | |
TLP1245LHM | 0.2-1.2 | Fixed≦ 0.5 | 1.0-4.5 | Fixed≦ 0.6 |
Manual | Manual | 2.5 | 4.8 |
Form | Model | Reset Form | Contact Form | Description |
Low Pressure | TLP2, TLP3
TLP6, TLP10 |
Automatic | ![]() |
â‘ : Common contact
①-③: Turn on when the pressure rises ①-⑤: Turn on when pressure drops M: Manual reset |
TLP6M | Manual | ![]() |
||
High Pressure | TLP12D,TLP16D
TLP20D,TLP30D TLP12L,TLP45DL |
Automatic | ![]() |
â‘ : Common contact
①-③: Turn on when the pressure drops ①-⑤: Turn on when pressure rises M: Manual reset |
TLP30, TLP45L | Automatic (Differential pressure fixed value) | ![]() |
||
TLP30M | Manual | ![]() |
||
High and low pressure | TLP830
TLP1245L |
Automatic | ![]() |
L: Low-voltage side
H: High voltage side M: Manual reset ↑ : Direction of action when pressure rises ↓ : Direction of action when pressure drops |
TLP830HM
TLP1245LHM |
High pressure automatic, low pressure manual | ![]() |
||
TLP830HLM
TLP1245LHLM |
High and low pressure manual | ![]() |
Single Group
Form | A | B | C |
Low Pressure | 34.4 | 36 | 22.4 |
High Pressure | 22 | 32.7 | 18.5 |
Double  Group