TYK-18H Explosion-proof Pressure Controller
■ The controller uses a combination of piston and diaphragm type sensors
■ Can be used for compressed air containing oil mist which have no corrosion to the material of the pressure sensors
■ Can be used for oil mist gas and hydraulic oil, water-oil emulsion and good lubricating properties of neutral liquid media which have no corrosion to the material of the pressure sensors
■ The setting value of the controller is adjustable, and the adjustment range is 0.3~40MPa
■ For neutral gases containing oil mist
- Price Term: FOB/CIF/EXW/DAP
- Package: Exported Wooden case or according to customer request
- Delivery Time: 7 to 10 working days
- Transports: By sea, by air, by high express
- Shipment Port: Shanghai Port
- Origin of Place: Jiangsu
- Warranty: 12 Months
- Main Technical Performance
- Specification
- External Dimensions And Mounting Dimensions (Unit: mm)
Normal Type | Explosion-proof | |
Operating Viscosity | <1×10-3m2/s | <1×10-3m2/s |
Switching Element | Micro switch | Sealed Switches |
Explosion Protection Class | — | Exde Ⅱ CT4~T6 Certificate of Conformity No |
Enclosure Protection Level | IP54 for grooved seals, IP65 for O-rings (according to DIN40050, equivalent to IP65 in GB4208) | IP54 for grooved seals, IP65 for O-rings (according to DIN40050, equivalent to IP65 in GB4208) |
Ambient Temperature | -20℃~40℃ | -20℃~40℃ |
Medium Temperature | 0~100℃ | 0~120℃ |
Installation Position | Pressure connection vertical down (15° tilt allowed) | Pressure connection vertical down (15° tilt allowed) |
Anti-Vibration Performance | Max: 40 m/s2 | Max: 20 m/s2 |
Repeatability Error | ≤2.5% | ≤2.5% |
Contact Capacity | AC 220V 6A (Resistance) | DC 250V 0.25A(Resistance) 60Wmax
AC 220V 6A(Resistance) 1250VAmax |
YTK-18H Switching Difference Is Not Adjustable
Set Value
Adjustment Range Mpa |
Switching
Difference Is Not Greater Than Mpa |
Maximum Allowable Pressure
①Mpa |
Switching Times
Times/Min
|
Pressure Sensor Materials | Interface Thread
② |
W
(Kg) |
Dimension
Drawing |
||
Housing | Diaphragm | Piston | |||||||
0.3~4 | 0.9 | 30 | 20 | Brass | Fluorine rubber | Steel | M20×1.5 | 0.8 | 01 |
0.5~6.3 | 1.3 | ||||||||
0.5~10 | 1.6 | ||||||||
0.5~16 | 1.9 | ||||||||
1~25 | 2.5 | 30 | 30 | 02 | |||||
1~40 | 2.8 | 60 | 30 |
YTK-18H Switching Difference Is Adjustable
Set Value
Adjustment Range Mpa |
Switching
Difference Is Not Greater Than Mpa |
Maximum Allowable Pressure
①Mpa |
Switching Times
Times/Min |
Pressure Sensor Materials | Interface Thread
② |
W
(Kg) |
Dimension
Drawing |
||
Housing | Diaphragm | Piston | |||||||
0.3~4 | 1.3 | 30 | 20 | Brass | Fluorine rubber | Steel | M20×1.5 | 0.85 | 01 |
0.5~6.3 | 1.6 | ||||||||
0.5~10 | 1.6 | ||||||||
0.5~16 | 2.2 | ||||||||
1~25 | 2.8 | 30 | 30 | 02 | |||||
1~40 | 4 | 60 | 30 |
YTK-18H Switching Difference Is Not Adjustable (Small Switching Difference)
Set Value
Adjustment Range Mpa |
Switching
Difference Is Not Greater Than Mpa |
Maximum Allowable Pressure
①Mpa |
Switching Times
Times/Min |
Pressure Sensor Materials | Interface Thread
② |
W
(Kg) |
Dimension
Drawing |
||
Housing | Diaphragm | Piston | |||||||
0.3~4 | 0.8 | 30 | 20 | Brass | Fluorine rubber | Steel | M20×1.5 | 0.85 | 01 |
0.5~6.3 | 1.2 | ||||||||
0.5~10 | 1.4 | ||||||||
0.5~16 | 1.6 | ||||||||
1~25 | 1.2 | 30 | 30 | 02 | |||||
1~40 | 1.8 | 60 | 30 |
Note: ①In actual operation, even brief pressure peaks are not allowed to exceed this value.
②If there are special requirements at the interface, specify in the order.
Adjustment Of The Set Value
See the adjustment of the set value of the pressure controller for details in Example 1, Example 2 and Example 5
Selection And Installation
See selection and installation of the controller for details
Normal Type
01
02
Explosion-proof type
03
04